the lugs on the exhaust nozzle connector are engaged with the
grooves on the connector of unit (Fig. 2).
3. Attach the exhaust nozzle (9) to the exhaust nozzle connector (10).
4. Extend the exhaust hose (11) and close the window as far as
possible trapping the exhaust nozzle (9)
INSTALLATION INSTRUCTIONS
Air Conditioning with Installation
If required your appliance can also be installed semi-permanently
(Fig. 5).
Proceed as follows:
1. Drill a hole in an outside wall, through a door or a window pane.
The hole should be no larger than 125mm, and between 35cm and
100cm from floor level. If you drill through a wall, we recommend
that you insulate that section with suitable materials. (Figs. 6-7)
2. Fit the flange accessory fixture (12) provided into the hole.
3. Fit the exhaust hose in the housing at the back of the appliance
(Fig. 2).
4. Insert the other end of the exhaust hose to the flange already
placed in the hole (Fig. 7).
NOTE: When installing the air conditioner semi-permanently, you
should leave a door slightly open (as little as 1cm) to guarantee
sufficient ventilation.
OPEREATING INSTRUCTIONS: CONTROL PANEL
Power Control
The power control turns the unit on and off.
Warning Light
Condensed water may accumulate in the unit. If the internal tank
becomes full, the warning light in the LCD Display will light up and
the unit will not operate until the unit has been drained.
Mode Control
The Mode Control has 3 settings: Cool, Dehumidify, and Fan. The
settings are adjusted with the Mode Control button. A light will
indicate which setting is being used.
1. Cooling Mode
When cool mode is selected,
will show in the LCD display.
During the cooling mode the air is cooled and hot air is exhausted
to the outside air through the exhaust tube. Adjust fan speed and
temperature to suit your desired comfort level.
Note : The air exchange hoses must vent outside the room when
using Cooling Mode.
2. Dehumidify Mode
When dehumidify mode is selected,
will show in the LCD
display. Air is dehumidified as it passes through the air conditioner
without being in full cooling mode. If the room temperature is
>25°C (77°F), fan speed can be adjusted; otherwise, fan speed is
set at Medium.
Note : The warm air exchange hoses must vent inside the
room when using Dehumidify Mode, not outside as it does
when cooling. If the unit is vented outside some cooling
will occur.
3. Fan Mode
When fan mode is selected,
, or will be shown in the LCD
display. Air is circulated throughout the room with no cooling.
Note: Unit does not need to be vented in Fan Mode.
Fan Speed Control
The Fan Speed Control has 3 settings:
High;
Medium; and Low.
Time Setting
Auto Shut Off: With machine in running mode, press the timer
button. Press “+” or “-” to select number of hours you would like
the unit to run before it automatically shuts off.
Auto Turn On: With machine in stand-by mode, press the timer
button. Press “+” or “-” to select number of hours before the unit
automatically starts running in air conditioning mode.
NOTE: Time is adjustable between 1-24 hours.
Temperature Controls
The temperature control buttons are used for adjusting the
thermostat.
The default LCD display is the room temperature.
• In cooling mode, when “+” or “-” is pressed the set temperature
is displayed and may be adjusted. After 15 seconds the display will
revert back to showing the room temperature. Temperature is only
adjustable in cool mode.
NOTE: By pressing both the “+” and “-” buttons at the
same time for more than 3 seconds, the display will toggle
between Celsius and Fahrenheit.
OPERATING INSTRUCTIONS: REMOTE Control
The functions work the same a your air conditioner’s control panel.
All key functions can be accessed from the remote control (Fig. 10).
Power Control: On/Off
Fan Speed Control:
High;
Medium; Low
On/Off Timer Control:
In running mode: Auto switch off
In stand-by mode: Auto switch off
Press
or button to adjust the time setting in 1 hour
intervals.
Fahrenheit/Celsius Button: toggles between Celsius and
Fahrenheit settings.
LCD Display
Time/Temperature Set Control:
• Used for adjusting the timer and temperature.
The default display on the control panel is room
temperature
When
or button is pressed in cool mode the set
temperature is displayed and may be adjusted. After 15 seconds
the display will revert back to room temperature.
Timer setting is available from 1-24 hours by pressing the
or
”button. button.
Mode Control: Press to change the operating mode, which will
rotate through Cool - Dehumidify - Fan and back to Cool.
ENGLISH
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell amh 10000 e at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell amh 10000 e in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 8,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info