367938
5
Zoom out
Zoom in
Previous page
1/88
Next page
5
IMPORTANT SAFETY INSTRUCTIONS
Read through all the instructions before starting to use the air-
conditioner. Keep this manual in a safe place for future reference.
1. Supervision is needed when the air-conditioner is used
anywhere near children. This appliance is not intended for use by
children or other persons without assistance or supervision if their
physical, sensory or mental capabilities prevent them from using
it safely.
2. Do not use the air-conditioner outdoors.
3. Stand the air-conditioner upright on a firm, even surface. Make
sure it is standing securely so that it cannot tilt or fall over. Water
can damage furniture and floor coverings.
4. Unwind the power cord completely. An incompletely unwound
power cord can lead to overheating and cause a fire.
5. If the power cord of the air-conditioner is damaged, it must be
repaired by a workshop that is approved by the manufacturer, as
special tools are needed.
6. Do not use an extension cord or a variable speed controller. This
can lead to overheating, fire or electric shock.
7. Only connect the air-conditioner with a single-phase earthed
power socket with the current stipulated on the type plate.
8. Switch the air-conditioner off and always pull the power plug
out of the power socket when the air-conditioner is not in use, or
when it is moved, handled or cleaned. Do not tug at the cord when
disconnecting the power plug.
9. The air-conditioner functions best at room temperatures of up
to 35°C.
10. Do not use the air-conditioner near easily inflammable gases
or materials, near an open fire, or in a location where oil or water
could splash. Do not spray insecticides or similar substances onto
the air-conditioner. Make sure that the air-conditioner is not
exposed to direct sunshine. Do not operate the air-conditioner in a
hothouse or a laundry, or near a bathtub, a shower or a swimming-
pool.
11. Do not use the air-conditioner outdoors. The air-conditioner is
intended only for domestic use indoors, in accordance with the user
manual, and is not intended for industrial use.
12. Before starting to operate the air-conditioner, make sure that
the air intakes (3, 8) and air outlet (1) are open. The air-conditioner
must not be positioned behind curtains or drapes, or behind other
objects or obstacles which could hinder the air circulation. Make
sure that no objects can get into the air intakes (3, 8) and air outlet
(1), as this can lead to overheating, fire or electric shock.
13. Do not direct the air outlet (1) directly towards people, plants,
pets, walls, furnishings or objects.
14. Do not pull the power plug out of the power socket when the
air-conditioner is in use.
First press the power button to the
OFF position.
15. After switching the air-conditioner off, wait for 3-5 minutes
before switching it back on again, as the compressor could
otherwise be damaged.
16. Do not immerse the air-conditioner in water or any other
liquids and do not pour water or any other liquids over the unit or
into the air intake (8) or air outlet (1).
17. Clean the air-conditioner regularly by following the cleaning
instructions.
18. When you take the air filter out of the air-conditioner, make
sure that you do not touch any metal parts. These are sharp-edged
and could cause injury.
Do not use the air-conditioner when the air
filter and air intakes (3, 8) are not installed.
19. If the power cord of the air-conditioner is damaged, it must be
repaired by a workshop that is approved by the manufacturer, as
special tools are needed.
20. Always transport the air-conditioner in an upright position.
If this is not possible, lay the unit on its side and stand it upright
as soon as you reach your destination. Wait at least 4 hours after
transporting the unit before starting to use it.
21. Do not operate the air-conditioner if it is damaged or looks as if
it might be damaged, or if it is not working properly. Pull the power
plug out of the power socket.
COMPONENTS
1. Air Outlet
2. Control Panel
3. Evaporator Air Intake
4. Air Outlet Hose
5. Casters
6. Power Supply with Plug
7. Drainage Pipe
8. Air Intake
9. Exhaust Nozzle
10. Exhaust Nozzle Connector (2 pcs.)
11. Exhaust Hose
12. Flange Accessory Fixture
13. Window Connector Cap
WARNINGS
1. All wiring must comply with local and national electrical codes
and be installed by a qualified electrician If you have any questions
regarding the following instructions, contact a qualified electrician.
2. Check available power supply and resolve any wiring problems
before installation and operation of this unit.
3. For your safety and protection, this unit is grounded through the
power cord plug when plugged into a matching wall outlet. If you
are not sure whether the wall outlets in your home are properly
grounded, please consult a electrician. Do not use plug adapters or
extension cords with this unit. If it is necessary to use an extension
cord with extension cord only ( available at most local hardware
stores).
INSTALLATION INSTRUCTIONS
Connect exhaust hose assembly to the back of the unit. Extend
hose to desired length and locate the exhaust nozzle through the
window for ventilation (Fig. 1).
Exhaust Duct Set Assembly and Installation
1. Insert ends of exhaust hose (11) into exhaust nozzle connector
(10) by twisting counter-clockwise until it stops.
2. Attach one exhaust nozzle connector (10) onto the rear outlet of
the unit. This is achieved by sliding the exhaust nozzle connector of
hose downward over the exhaust outlet of unit (4) ensuring that
ENGLISH
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell airconditioner amh 12000e at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell airconditioner amh 12000e in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info