ENGLISH
PUMP PERFORMANCE
The maximum pump discharge capacity is determined when pumping
clear water at 0 meters total head and at sea level. As the total head
[1] (discharge head [2] + suction head [3]) increases, pump discharge
capacity decreases (see figure). If the pump is used at higher
elevations, pump discharge capacity may also decrease. Other
factors affecting pump discharge capacity are:
The type of chemical being pumped.
The length and type of the suction and discharge hose used.
Oil Alert® System
The Oil Alert system is designed to prevent engine damage caused by
an insufficient amount of oil in the crankcase. Before the oil level in
the crankcase can fall below a safe limit, the Oil Alert system will
automatically shut down the engine (the ignition switch will remain in
the ON position).
If the engine stops and will not restart, check the oil level (page 8)
before troubleshooting in other areas.
STARTING THE ENGINE
1. Turn the fuel valve [1] to
the ON position.
2. Move the choke lever [2]
to the CLOSED position.
Do not use the choke if
the engine is warm or
the ambient
temperature is high.
3. Turn the ignition switch
[3] to the ON position.
4. Move the throttle lever
[4] slightly to the left.
5. Pull the starter grip
lightly until resistance is
felt, then pull it briskly.
NOTICE
Return the starter grip
slowly back to the engine to prevent damage to the starter.
6. As the engine warms
up, gradually move the
choke lever [5] to the
OPEN position.
Pump Performance (Maximum with clear water)
Total head [1] 32 m
Suction head [3] 8 m
Discharge capacity 833 l/min
Self-priming time 65 sec at 5 m
Pressure 310 kPa
[2]
[3]
[1]
[1]
ON
[2]
CLOSED
ON
[3]
[4]
[5]
OPEN
WMP20XE.book Page 6 Thursday, August 28, 2008 2:43 PM
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honda WMP20XE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honda WMP20XE in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 10,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info