NOTE: This generator set has been built to current standards and designed to satisfy a wide range of applications.
Remember however that every application is subject to strict electrical, accident prevention and sanitary standards. For this reason
the generator set should be considered as an integral part of a system that should be designed, tested and approved by qualified
technicians and/or companies.
• In order to avoid electrical accidents, all connections to the distribution panel must be carried out by qualified technicians. Incorrect
connections can harm people and damage the generator set.
• Protection against indirect contacts: all the generator sets, during normal working, follow the law of electrical separation. However,
they can be supplied with various protection options (ELCB, isometer) by the manufacturer upon specific request, or they can be
protected in the same way during installation by the user.
It is therefore important to follow the following instructions:
1) Standard generator set: protected by electrical separators. This equipment has a thermal protection device and/or a magnetothermal
device to protect against overload, over-current and short-circuit.
In these cases the generator set should under no circumstances be grounded using the terminal “PE” or with any other part of the
generator set.
2) Generator set with optional switchboard (or with other devices installed by the user): protected by a circuit breaker which
automatically cuts off the power supply. It has thermal circuit breaker and/or magnetothermal switches combined with differential
circuit breakers or insulation monitors. In this case the generator must be connected to a ground plate through the terminal “PE”, via an
insulated yellow-green conductor with a suitable section.
WARNING: in the event of differential circuit breakers installation, it is important for its correct operation that:
A) On single-phase generator sets the neutral point that corresponds to the joint of the two main windings is also grounded.
B) On three-phase generator sets the neutral point that corresponds to the star point in the case of a star connection is also grounded.
In the case of a delta connection it is not possible to install a differential switch.
• The generator set is preset for grounding the masses; a special screw, marked with the symbol PE, allows all the metal parts of the
generator set to be connected to a ground plate.
• Do not connect to the generator set any appliances with unknown electrical specifications or with specifications different from those
of the generator set (i.e. different voltages and/or frequencies).
• The electrical circuit of the generator set is protected by a switch, which is either magnetothermal, magnetothermal-differential or
thermal type. In case of overload and/or a short-circuit the power will be cut immediately. To reset the power, disconnect all
appliances, check the cause of the short-circuit and/or overload and reset the switch.
• If using the generator set as battery charger (where available), place the battery at a distance of 1 m from the generating set, making
sure that the filler plugs are removed from the cells. Take care to observe the battery polarities, incorrect connection of positive and
negative poles could cause the battery to explode.
WARNING: During charging, the battery gives off inflammable vapour. Therefore observe the maximum caution while
charging and keep children far away.
• With a star-delta switch the following options are available:
THREE PHASE 4OO V (full design load)
SINGLE PHASE 230 V (1/3 of design load)
THREE PHASE 230V (full design load)
SINGLE PHASE 230 V (2/3 of design load)
When set on “O” all power points are disconnected.
• Before setting the switch to any of the above, make sure that no appliances are connected to the generator set. Be sure to set the
switch to the correct current as shown on the tag, in order to avoid damages to the appliances.
- When the generator set is in use, do not place any objects on the frame or directly on the engine: any foreign bodies may jeopardize
its performance.
• Do not hinder the normal vibrations that the generator set makes when in use. The silent-blocks are of an adequate size to work
properly.
MOTOR WELDING SET SECTION
Connect the welding sockets through cables of a suitable cross section -refer to table 1. Choose the right polarity according to the
type of electrode to be used -refer to the electrode manufacturer’ s instructions.
Open the accelerator handle in order to obtain the right welding current according to the rpm.
By turning it clockwise the rpm is increased, thus increasing also the welding current. By turning the accelerator handle anticlockwise
the rpm is reduced, thus reducing also the welding current.
DOUBLE POSITIVE TERMINAL
When using electrodes of diameter 3.25 mm or lower place the clamp on the positive “Max 140A” terminal. When using electrodes of
diameter above 3.25 mm place the clamp on the positive “Max power” terminal. This allows better welding arc quality. When using
cellulose electrodes, it is advisable to keep the clamp on the + 140 terminal also for diameters above 3.25 mm.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honda ESE 604 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honda ESE 604 in the language / languages: All languages as an attachment in your email.

The manual is 1,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info