GENERATING SET USE
INFORMATION ON THE CONSTRUCTION OF THE GENERATING SET
The generator windings are not connected to the earth; the system is thus safe by construction
and limits the risks of electrocution. It is strictly forbidden to connect the coils to the generator
earth, except when using a 30 mA differential circuit breaker for the protection of persons. The
installation of such a device must be carried out by a specialist electrician and requires all
appliances to be earthed.
The differential circuit breaker actsasa check against faulty insulation.Itcutsoff the power when
there is a detectable fault in the insulation between a voltage-bearing conductor and any part of
the earth, on the output side of the differential circuit breaker.
ECT6D (230/400 V)
The two 230 V single-phase receptacles are connected in parallel to the terminals of a winding
specially reinforced to withstand a current of 20 A. The single-phase 230 V power output given
on the rating plate, and also indicated in the table of characteristics, is available only on these
receptacles and when no other three-phase load is connected to the generator’s outputs. Never
connect the generator’s three-phase receptacle to a single-phase splitter box.
When using simultaneously 230 V single-phase and 400 V three-phase current, the current
intensity per phase must not exceed 10 A.
14
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honda ECT6D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honda ECT6D in the language / languages: English as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Honda ECT6D

Honda ECT6D User Manual - German - 24 pages

Honda ECT6D User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info