36
The triggering of the button is entered in the „if query“
and the required function of the actuator concerned is
entered in the „then function“.
To „toggle“ the actuator, the required response can be
entered in the „if“ or „else“ function by checking the
status of the actuator concerned.
Example:
If button X on the status indicator is pressed and the
status of actuator YZ is „switching state on“ (action
„check only“), change switching state to „switching
state off“ immediately.
If the actuator is then off when the button is pressed,
the connection branches to „else“.
„Switching state to „switching state off“ immediately“
must be entered here and the actuator is switched off.
The previously assigned actions can be triggered via
the three buttons on the rear of the device. The selec-
tion is monitored via the LED‘s of the display eld.
- Select the required channel using the LED display by
pressing the up or down button. This is indicated by
rapid ashing in orange.
- Whilst the LED is ashing, briey press the „Send“
button. Now the LED illuminates in orange during
transmission, then in green for approx. 1 second
after successful receipt at the central control unit.