518476
4
Zoom out
Zoom in
Previous page
1/29
Next page
76
GB
GB
Figure 8
Front Plate
PumpInlet
Impeller
T
ubing
H
ousing
SuctionFeet
FlowControlLever
TROUBLESHOOTING :
If the pump fails to operate, check the following:
Check the circuit breaker, or try a different outlet to make sure the pump is getting electrical
power.
NOTE: Always disconnect from electrical outlet before handling the pump.
Check the pump discharge and tubing for kinks and obstructions. Algae build up can be flushed
out with a garden hose.
Remove the pump inlet to access the impeller area. Turn the rotor to ensure it is not broken or
jammed.
Monthly maintenance will add to your pump’s life.
NOTE: Ensure that the electrical cord loops below the electrical outlet to form a ‘Drip Loop’. This
will prevent water from running down the cord into the electrical outlet.
If the pump gurgles, spews, or “burps”:
Check the water level to make sure the pump has enough water to function.
Obtaining a desired water level:
Check the water level daily the first week to measure the rate of evaporation; refill with water as
needed.
If water is splashing outside the fountain:
Rocks that are hit by water and also touch the edge of the base will cause water to splash
outside of the base and contribute to the splash factor. Expect some splash to occur as you get
the rocks organized.
If splash continues, adjust the flow control valve to a lower setting, and/or rearrange
the river rocks by moving them away from the edge of the base.
CAUTION:
All servicing of this fountain must be performed by authorized HoMedics
service personnel only.
ATTENTION:
In order to get best results, please operate pump completely submerged.
Keep the water level above the minimum water level ALL THE TIME.
MAINTENANCE :
To clean the pump:
Unplug from electrical outlet. Remove it from the base of the fountain. Use a small brush or
stream of water to remove any debris (Fig 8).
To keep water clean:
Periodically change water and clean the product according to the water condition. Keeping the
water clean prevents the water from becoming sticky and forming micro-organisms.
To clean off hard water deposits on the base or rocks:
Soak the container and rocks in a mixture of vinegar and water to clean and remove any mineral
build-up.
Keeping the water at an optimum level:
Add water periodically to keep water level at an optimum level to avoid shortening the life of the
pump.
NOTE: Never let the pump run dry, as this will shorten the life of the pump.
Fountain Storage
Unplug the fountain from the electrical outlet, empty the water, and store rocks and fountain in a
dry, cool place.
Plug (MODEL WFL-RVRB-3GB ONLY)
If the plug on this appliance is damaged, it can be replaced
with a BS 1363 plug, fitted with a 3A BS 1362 fuse.
Only use a 3amp fuse with this appliance.
Care must be taken when changing the plug.
If in doubt, contact a qualified electrician.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Homedics WFL-RVRB-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Homedics WFL-RVRB-2 in the language / languages: English, German, Dutch, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info