How to use the blood pressure device
Setting date and time
1. To set date and time, press the SET button located on the back of the blood
pressure device.
2. The number designating hours flashes on the display. The time setting is changed by pressing
the button. Every push increases the number by one and when the desired number
appears on the display it is confirmed by pressing the SET button . The number
designating minutes now flashes on the display.
3. The settings for minutes and date are set in the same way as described in 2.
4. When the device is ready for measurement, ‘0’ will appear on the display.
Fitting the cuff
1. If the cuff is not assembled at first use, put the end of the cuff which is furthest away from the
tube through the D-ring to form a noose.
2. Apply the tube to the left side of the device.
3. Remove tight-fitting clothing from your left upper arm and position the cuff at approximately
2-3 cm above the elbow so that the tube is centered at the middle of the arm. The tube must
face downward towards the hand.
How to use the blood pressure monitor
This blood pressure monitor is equipped with ‘Smart Sense
T
M
technology. By pressing a single
button the cuff is automatically inflated to block the blood pressure flow through the artery.
Subsequently, the deflation process starts. The ‘Smart Sense
TM
technology enables automatic
inflation and deflation to be adjusted exactly to fit each individual. Please be aware that any
motion during inflation or deflation will cause measurement errors. When the measurement is
complete the display will show the systolic pressure, the diastolic pressure, and the heart rate.
Smart Sense
TM
technology is approved to provide clinically correct results. The device is
approved by and in accordance with the demands of MDD (Medical Device Directive, European
Norm EN-1060-3 &/or 1060-4) as well as the guidelines from The British Hypertension Society
(BHS) accreditation and the Food & Drug Administration (FDA) AAMI/ANSI SP10.
Based on the measurements, the blood pressure monitor’s category indicator will warn the user
by means of a symbol if the user falls within a risk group. Read more about this in the section
Risk category indicator and consult the table on page 48.
The blood pressure monitor is also equipped with an identification function for heart arrhythmia
(heart rhythm disturbances) which will warn the user that his or her heart has an unstable
heartbeat. If the symbol
IHB
appears frequently (5 successive measurements or more) it is
highly recommended that you consult a doctor. Read more about this in the section ‘Establishing
arrhythmia (heart rhythm disturbances)’.
Description of the parts
4
GB
GB
LCD display
User select
button
START/STOP button
Memory button
Air tube and connector
D-ring cone and arm cuff
Date/Time set buttons
(located on back of unit)
2
~
3
c
m
(
0
8
~
1
2
)
a
a
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Homedics BPA-200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Homedics BPA-200 in the language / languages: English as an attachment in your email.

The manual is 3,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info