467122
19
Zoom out
Zoom in
Previous page
1/52
Next page
– 19 –
ENGLISH
DEUTSCHFRANÇAISITALIANOSPANISHPORTUGUÊS
∂ÏÏËÓÈο
РУССКИЙ
RAR-3R5
INTERNAL CLEANING OPERATION
Press the (FUNCTION SELECTOR) button again until
(INTERNAL CLEAN) blinks.
While (INTERNAL CLEAN) is blinking, point the remote controller
towards the unit and press the (ON/OFF) button.
A short beep sounds and (INTERNAL CLEAN) indicator turns off
on the remote controller.
STOP
The internal cleaning operation is automatically performed after cooling, dehumidifying or Dry Cool operation
to control mold growth by configuring the (INTERNAL CLEAN) operation. (There is no mold removing
function and disinfecting/sterilizing effect.)
Press the
(FUNCTION SELECTOR) button
until (INTERNAL CLEAN) blinks.
While (INTERNAL CLEAN) is blinking, point the remote controller
towards the unit and press the (ON/OFF) button.
A short beep sounds and (INTERNAL CLEAN) indicator turns on
at the remote controller.
It will automatically stop after 1 hour of operation.
1
2
Internal cleaning operation is not performed if the duration of cooling, dehumidifying or Dry Cool operation is
too short (below approximately 10 minutes).
If the internal cleaning mode is set, the internal cleaning operation will automatically start when cooling,
dehumidifying or Dry Cool operation is stopped. During internal cleaning, the heating operation and fan
operation (with Stainless Plasma Air Purifying) are performed to control the mold growth inside the indoor
unit.
While (ON TIMER) is set, internal cleaning operation is not performed from 2 hours before the preset
time.
Internal cleaning operation is not performed if the air conditioner operation is stopped in any of the following
conditions below.
(Heating operation, Stainless Plasma Air Purifying operation, Quick Laundry operation and (OFF TIMER)
stop under Condensation Control operation, operation stopped by (SLEEP) button.)
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hitachi RAS-25SX8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hitachi RAS-25SX8 in the language / languages: English as an attachment in your email.

The manual is 5,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info