566492
13
Zoom out
Zoom in
Previous page
1/82
Next page
English
12
MAINTENANCE AND INSPECTION
1. Inspecting the drill bits
Since use of a dull tool will cause motor
malfunctioning and degraded efficiency, replace the
drill bit with new ones or resharpen them without
delay when abrasion is noted.
2. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure
that they are properly tightened. Should any of the
screws be loose, retighten them immediately. Failure
to do so could result in serious hazard.
3. Maintenance of the motor
The motor unit winding is the very ”heart” of the
power tool. Exercise due care to ensure the winding
does not become damaged and/or wet with oil or
water.
4. Inspecting the carbon brushes (Fig. 18)
The motor employs carbon brushes which are
consumable parts. When they become worn to or
near “wear limit”, it could result in motor trouble.
When an auto-stop carbon brush is equipped, the
motor will stop automatically.
At that time, replace both carbon brushes with new
ones which have the same carbon brush numbers
shown in Fig. 18.
In addition, always keep carbon brushes clean and
ensure that they slide freely within the brush holders.
5. Replacing a carbon brush (Fig. 19)
Disassembling
(1) Loosen the three screws on the handle cover, and
remove the handle cover.
(2) Lift out the brush holder together with the carbon
brush, while being very careful not to forcibly pull
the lead wires within the brush holder.
(3) Withdraw the brush terminal, and remove the carbon
brush from the brush holder.
Reassembling
(1) Place a new carbon brush into the brush holder, and
connect the brush terminal to the carbon brush.
(2) Return the brush holder and other parts to their
original positions, as illustrated in Fig. 19.
(3) Place the lead wire in the specified position. Be very
careful not to allow the lead wire to contact the
armature or rotating parts of the motor.
(4) Replace the handle cover, while being careful to
ensure it does not pinch the lead wire, and secure it
firmly with the three screws.
CAUTION:
Should the lead wire be pinched by the handle cover
or come in contact with the armature or rotating
parts of the motor, a serious danger of electric shock
to the operator will be created. Excercise extreme
caution in disassembling and reassembling the motor,
following the above procedures exactly.
Do not attempt to disassemble any parts other than
those necessary to effect replacement of the carbon
brush.
6. Service parts list
A: Item No.
B: Code No.
C: No. Used
D: Remarks
CAUTION:
Repair, modification and inspection of Hitachi Power
Tools must be carried out by an Hitachi Authorized
Service Center.
This Parts List will be helpful if presented with the
tool to the Hitachi authorized Service Center when
requesting repair or other maintenance.
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
MODIFICATION:
Hitachi Power Tools are constantly being improved
and modified to incorporate the latest technological
advancements.
Accordingly, some parts (i.e. code numbers and/or
design) may be changed without prior notice.
NOTE:
Due to HITACHI’s continuing program of research and
development, the specifications herein are subject to
change without prior notice.
IMPORTANT:
Correct connection of the plug
The wires of the mains lead are coloured in accordance
with the following code:
Blue: -Neutral
Brown: -Live
As the colours of the wires in the mains lead of this tool
may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
The wire coloured blue must be connected to the terminal
marked with the letter N or coloured black. The wire
coloured brown must be connected to the terminal
marked with the letter L or coloured red. Neither core
must be connected to the earth terminal.
NOTE:
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not be
applicable to other markets except The United Kingdom.
Information concerning airborne noise and vibration
The measured values were determined according to
EN50144.
The typical A-weighted sound pressure level: 90 dB (A).
The typical sound power level: 103 dB (A).
Wear ear protection.
The typical weighted root mean square acceleration
value: 8.0 m/s
2
.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hitachi DH24PB-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hitachi DH24PB-2 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 2,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hitachi DH24PB-2

Hitachi DH24PB-2 Additional guide - English, German, Dutch, French, Italian, Portuguese, Spanish - 78 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info