20
Names Operation Type Header
Command Data
CRC Action Type Setting Code
RS-232C Communication / Network command table
BASS - MIU Get BE EF 03 06 00 85 FB 02 00 86 20 00 00
Increment BE EF 03 06 00 E3 FB 04 00 86 20 00 00
Decrement BE EF 03 06 00 32 FA 05 00 86 20 00 00
BASS - COMPONENT Get BE EF 03 06 00 C1 FB 02 00 85 20 00 00
Increment BE EF 03 06 00 A7 FB 04 00 85 20 00 00
Decrement BE EF 03 06 00 76 FA 05 00 85 20 00 00
BASS - S-VIDEO Get BE EF 03 06 00 B5 FA 02 00 82 20 00 00
Increment BE EF 03 06 00 D3 FA 04 00 82 20 00 00
Decrement BE EF 03 06 00 02 FB 05 00 82 20 00 00
BASS - VIDEO Get BE EF 03 06 00 F1 FA 02 00 81 20 00 00
Increment BE EF 03 06 00 97 FA 04 00 81 20 00 00
Decrement BE EF 03 06 00 46 FB 05 00 81 20 00 00
BASS - AUDIO OUT
STANDBY
Get BE EF 03 06 00 19 F8 02 00 8F 20 00 00
Increment BE EF 03 06 00 7F F8 04 00 8F 20 00 00
Decrement BE EF 03 06 00 AE F9 05 00 8F 20 00 00
SRS WOW - RGB1 Set TURN OFF BE EF 03 06 00 FE FF 01 00 90 20 00 00
MID BE EF 03 06 00 9E FE 01 00 90 20 02 00
HIGH BE EF 03 06 00 0E FF 01 00 90 20 03 00
Get BE EF 03 06 00 CD FF 02 00 90 20 00 00
SRS WOW - RGB2 Set TURN OFF BE EF 03 06 00 CE FE 01 00 94 20 00 00
MID BE EF 03 06 00 AE FF 01 00 94 20 02 00
HIGH BE EF 03 06 00 3E FE 01 00 94 20 03 00
Get BE EF 03 06 00 FD FE 02 00 94 20 00 00
SRS WOW - HDMI Set TURN OFF BE EF 03 06 00 BA FF 01 00 93 20 00 00
MID BE EF 03 06 00 DA FE 01 00 93 20 02 00
HIGH BE EF 03 06 00 4A FF 01 00 93 20 03 00
Get BE EF 03 06 00 89 FF 02 00 93 20 00 00
SRS WOW - MIU Set TURN OFF BE EF 03 06 00 76 FF 01 00 96 20 00 00
MID BE EF 03 06 00 16 FE 01 00 96 20 02 00
HIGH BE EF 03 06 00 86 FF 01 00 96 20 03 00
Get BE EF 03 06 00 45 FF 02 00 96 20 00 00
SRS WOW -
COMPONENT
Set TURN OFF BE EF 03 06 00 32 FF 01 00 95 20 00 00
MID BE EF 03 06 00 52 FE 01 00 95 20 02 00
HIGH BE EF 03 06 00 C2 FF 01 00 95 20 03 00
Get BE EF 03 06 00 01 FF 02 00 95 20 00 00
SRS WOW - S-VIDEO Set TURN OFF BE EF 03 06 00 46 FE 01 00 92 20 00 00
MID BE EF 03 06 00 26 FF 01 00 92 20 02 00
HIGH BE EF 03 06 00 B6 FE 01 00 92 20 03 00
Get BE EF 03 06 00 75 FE 02 00 92 20 00 00
SRS WOW - VIDEO Set TURN OFF BE EF 03 06 00 02 FE 01 00 91 20 00 00
MID BE EF 03 06 00 62 FF 01 00 91 20 02 00
HIGH BE EF 03 06 00 F2 FE 01 00 91 20 03 00
Get BE EF 03 06 00 31 FE 02 00 91 20 00 00
SRS WOW - AUDIO OUT
STANDBY
Set TURN OFF BE EF 03 06 00 EA FC 01 00 9F 20 00 00
MID BE EF 03 06 00 8A FD 01 00 9F 20 02 00
HIGH BE EF 03 06 00 1A FC 01 00 9F 20 03 00
Get BE EF 03 06 00 D9 FC 02 00 9F 20 00 00
MUTE Set TURN OFF BE EF 03 06 00 46 D3 01 00 02 20 00 00
TURN ON BE EF 03 06 00 D6 D2 01 00 02 20 01 00
Get BE EF 03 06 00 75 D3 02 00 02 20 00 00
SPEAKER Set TURN OFF BE EF 03 06 00 6E D5 01 00 1C 20 00 00
TURN ON BE EF 03 06 00 FE D4 01 00 1C 20 01 00
Get BE EF 03 06 00 5D D5 02 00 1C 20 00 00
229


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hitachi CP-X809W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hitachi CP-X809W in the language / languages: Swedish as an attachment in your email.

The manual is 6,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hitachi CP-X809W

Hitachi CP-X809W User Manual - English - 235 pages

Hitachi CP-X809W Additional guide - German - 235 pages

Hitachi CP-X809W User Manual - German - 235 pages

Hitachi CP-X809W User Manual - Dutch - 235 pages

Hitachi CP-X809W User Manual - French - 235 pages

Hitachi CP-X809W User Manual - Italian - 235 pages

Hitachi CP-X809W User Manual - Polish - 235 pages

Hitachi CP-X809W User Manual - Portuguese - 235 pages

Hitachi CP-X809W User Manual - Spanish - 235 pages

Hitachi CP-X809W User Manual - Norwegian - 235 pages

Hitachi CP-X809W User Manual - Finnish - 235 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info