Tool The tool does not trim well. The blade has become dull.
[Shrub shear]
The blade stopped because it was
used to cut a branch whose width
exceeded the blade’s cutting
capacity.
NOTE
Work that will repeatedly cause
the blade to stop will eventually
damage the motor.
Use a wire brush or other tool to
remove sap and rust and use a file
or whetstone to sharpen the blade.
If these efforts fail to make the
blade sharper, the blade has
reached the end of its service life.
Replace the blade with a new one.
Some garden trees have wood that
is very hard and may be beyond
the capacity of the tool even if it is
of a width that is within normal
capacity. Use a pair of pruning
shear to remove thick branches
before starting work.
An oblique cut may also exceed
the capacity of the tool since the
length of the cut increases. Be sure
to trim thick branches at right
angles.
Symptom Possible cause Remedy
GUARANTEE
We guarantee Hitachi Power Tools in accordance with
statutory/country specific regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling
instruction, to a Hitachi Authorized Service Center.
NOTE
Due to HITACHI’s continuing program of research and
development, the specifications herein are subject to
change without prior notice.
Information concerning airborne noise and vibration
The measured values were determined according to
EN60745 (CH10DL) or IEC60335 (CG10DL) and declared
in accordance with ISO 4871.
Measured A-weighted sound power level:
81 dB (A) (CH10DL)
84 dB (A) (CG10DL)
Measured A-weighted sound pressure level:
70 dB (A) (CH10DL)
81 dB (A) (CG10DL)
Uncertainty KpA: 3 dB (A).
Wear ear protection.
Vibration total values (triax vector sum) determined
according to EN60745 or IEC60335.
No load:
a
h
= 1.7 m/s
2
, Uncertainty K = 1.5 m/s
2
(CH10DL)
a
hw
= 1.9 m/s
2
(CG10DL)
WARNING
The vibration emission value during actual use of the
power tool can differ from the declared value
depending on the ways in which the tool is used.
To identify the safety measures to protect the operator
that are based on an estimation of exposure in the
actual conditions of use (taking account of all parts of
the operating cycle such as the times when the tool is
switched off and when it is running idle in addition to
the trigger time).
01Eng_CH10DL_WE 9/30/09, 16:0217
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hitachi CH10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hitachi CH10 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info