563777
10
Zoom out
Zoom in
Previous page
1/92
Next page
10
English
ASSEMBLY PROCEDURES
Drive shaft to engine (Fig. 1)
Loosen tube locking bolt (1) about ten turns so that the bolt point
will not obstruct drive shaft tube to be inserted. When inserting drive
shaft tube, hold the tube locking bolt outward preventing inside tting
from obstructing as well.
Insert the drive shaft into the clutch case of the engine properly until
the marked position (2) on the drive shaft tube meets the clutch
case.
NOTE
When it is hard to insert drive shaft up to the marked position on
the drive shaft tube, turn drive shaft by the cutter mounting end
clockwise or counter-clockwise. Tighten tube locking bolt lining
up the hole in the shaft tube. Then tighten clamp bolt securely
(3).
Installation of attachment
1. Join the attachment in place of it.
2. Make sure the lock pin (4) ts in the location hole (5) of tube and
that the tube will not come o . (Fig. 2)
3. Tighten the knob nut (6) securely. (Fig. 2)
Installation of handle
WARNING
When you use steel/rigid blades on straight shaft trimmers or
brush cutters, always use a barrier bar (7) and shoulder harness
with the loop handle. (Fig. 3)
Attach the handle to the drive shaft tube with the angle towards the
engine.
Adjust the location to the most comfortable position before
operation.
NOTE
If your unit has handle location label on drive shaft tube, follow
the illustration.
Remove the handle bracket (8) from the assembly. (Fig. 4)
Place the handles and attach the handle bracket with four bolts
lightly. Adjust to appropriate position. Then attach it rmly with the
bolts.
Put stop cords (11) and throttle wire (9) through protective tube (10),
then unhook the hip pad. (Fig. 5)
Throttle wire / stop cord
Remove air cleaner cover. (Fig. 6)
Connect stop cords. (Fig. 8)
Connect throttle wire end to carburetor. (Fig. 9)
Convert throttle wire and stop cords together with protective tube
provided up to air cleaner cover. (Fig. 10)
Throttle cable and stop cord (Fig. 7A)
(for CG33EJ (SL))
Connect throttle cables (12) by hooking each cut end of the cables
and clamp the jointed part with connector case (13) which locks.
Connect each end of stop cords (14).
NOTE
When removing connector case, insert coin or minus driver in
slot in the middle and twist it.
Throttle wire / stop cord (Fig. 7)
(for CG27EJ (SLP)/(
SP)/(SLDP))
Remove air cleaner cover. (Fig. 6)
Connect stop cords. (Fig. 8)
If the throttle outer end (15) is threaded on your unit, screw it into the
cable adjuster stay (16) all the way, and then tighten this cable end
using the adjuster nut (17) against the cable adjuster stay (16).
Connect throttle wire end (18) to carburetor (19) and install swivel cap
(if so equipped) where is included in tool bag, onto swivel.
Cover throttle wire and stop cords together with protective tube
provided up to air cleaner cover. (Fig. 10)
Installation of blade guard (Fig. 11, 12, 13, 14)
NOTE
The guard bracket may come already mounted to the gear case
on some models.
Install the blade guard and the bracket spacers (20) (If so equipped)
on drive shaft tube against angle transmission. Tighten the guard
bracket rmly so that the blade guard does not swing or move down
during operation.
Install the blade guard to the guard bracket, which also secures the
guard to the gear case using the two guard mounting screws.
CAUTION
Some blade guards are equipped with sharp line limiters. Be
careful with handling it.
NOTE (Fig. 14)
When using Hitachi aluminum head (CH-100 or CH-300) on your
unit, the sharp line limiter (21) which is included in the tool bag,
should be securely fastened to the blade guard using the bolt
shown (22).
When using a trimmer head with two piece type blade guard, attach
the guard extension to the blade guard. (Fig. 15)
NOTE
When attaching the guard extension to the blade guard, the
sharp line limiter must be removed from the blade guard, (if so
installed).
If your unit has guard location label on drive shaft tube, follow the
indication.
To remove the guard extension, refer to the drawings. Wear
gloves as the extension has a sharp line limiter, then push the
four square tabs on the guard one by one in order. (Fig. 16)
Installation of cutting blade (Fig. 17, 18)
(If so equipped)
When installing a cutting blade, make sure that there are no cracks
or any damage in it and that the cutting edges are facing the correct
direction.
NOTE
When installing cutter holder cap (23), be sure to set concave
side upward.
Insert the alien wrench (24) into the hole of the angle transmission
in order to lock the cutter holder (25). Please note that the cutter
xing bolt or nut (26) has left-handed threads, (clockwise to
loosen/ counter-clockwise to tighten). Tighten the xing bolt or
nut with the box wrench.
CAUTION
Before operation, make sure the blade has been properly
installed.
If your unit is equipped with protection cover under a cutting
blade, check it for wear or cracks before operation. If any damage
or wear is found, replace it, as it is an article of consumption.
Installation of the Brain cutting head
NOTE
For installation see your Brain Owner's manual, provided with
the Brain cutting head.
WARNING
For Hitachi Brain heads or Hitachi alloy head, use only exible,
non-metallic line recommended by the manufacturer. Never use
wire or wire ropes. They can break o and become a dangerous
projectile.
000Book_CG27EJ(S)_WE_NE.indb 10000Book_CG27EJ(S)_WE_NE.indb 10 2012/06/21 12:18:032012/06/21 12:18:03
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hitachi CG28EJ at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hitachi CG28EJ in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 15,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info