160
9.2.7 Configuring Multicast
Purpose:
The multicast can be configured to realize live view for more than the maximum number of cameras through
network.
A multicast address spans the Class-D IP range of 224.0.0.0 to 239.255.255.255. It is recommended to use the
IP address ranging from 239.252.0.0 to 239.255.255.255.
Steps:
1. Enter the Network Settings interface.
Menu > Configuration > Network
2. Select the More Settings tab to enter the More Settings interface.
3. Set Multicast IP. When adding a device to the CMS (Client Management System) software, the
multicast address must be the same as the device’s multicast IP.
Figure 9. 29 Configure Multicast
4. Click the Apply button to save and exit the interface.
9.2.8 Configuring RTSP
Purpose:
The RTSP (Real Time Streaming Protocol) is a network control protocol designed for use in entertainment and
communications systems to control streaming media servers.
Steps:
1. Enter the Network Settings menu by clicking Menu > Configuration > Network.
2. Select the More Settings tab to enter the More Settings men.
Figure 9. 30 RTSP Settings Interface
3. Enter the RTSP port in the text field of RTSP Service Port. The default RTSP port is 554, and you
can change it according to different requirements.
4. Click the Apply button to save and exit the menu.
161


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hikvision DS-7208HWI-SH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hikvision DS-7208HWI-SH in the language / languages: English as an attachment in your email.

The manual is 9,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hikvision DS-7208HWI-SH

Hikvision DS-7208HWI-SH User Manual - German - 175 pages

Hikvision DS-7208HWI-SH User Manual - Dutch - 177 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info