SPECIFICATIONS
Model M12V2
Voltage (by areas)* (110 V, 230 V)
Power Input* 2000 W
Collet Chuck Capacity 12 mm or 1/2"
No-load speed 8000–22000 min-1
Main Body Stroke 65 mm
Weight (without cord and
standard accessories) 6.9 kg
* Be sure to check the nameplate on product as it is subject
to change by areas.
NOTE
Due to HiKOKI’s continuing program of research and
development, the speci cations herein are subject to
change without prior notice.
PRIOR TO OPERATION
1. Power source
Ensure that the power source to be utilized conforms
to the power requirements speci ed on the product
nameplate.
2. Power switch
Ensure that the power switch is in the OFF position. If the
plug is connected to a receptacle while the power switch
is in the ON position, the power tool will start operating
immediately, which could cause a serious accident.
3. Extension cord
When the work area is removed from the power source,
use an extension cord of su cient thickness and rated
capacity. The extension cord should be kept as short as
practicable.
4. RCD
The use of a residual current device with a rated residual
current of 30 mA or less at all times is recommended.
INSTALLING AND REMOVING BITS
WARNING
Be sure to switch power OFF and disconnect the plug
from the receptacle to avoid serious trouble.
1. Installing bits
(1) Clean and insert shank of bit into the collet chuck until
shank bottoms, then back it out approximately 2 mm.
(2) With the bit inserted and pressing the lock pin holding
the armature shaft, use the 23 mm wrench to rmly
tighten the collet chunk in a clockwise direction (viewed
from under the router). (Fig. 1)
CAUTION
Ensure that the collet chuck is rmly tightened after
inserting a bit. Failure to do so will result in damage to
the collet chuck.
Ensure that the lock pin is not inserted into the armature
shaft after tightening the collet chuck. Failure to do so
will result in damage to the collet chuck, lock pin and
armature shaft.
(3) When using the 8 mm diameter shank bit, replace the
equipped collet chuck with the one for 8 mm diameter
shank bit which is provided as the standard accessory.
2. Removing Bits
When removing the bits, do so by following the steps for
installing bits in reverse order. (Fig. 2)
CAUTION
Ensure that the lock pin is not inserted into the armature
shaft after tightening the collet chuck. Failure to do so
will result in damage to the collet chuck, lock pin and
armature shaft.
HOW TO USE THE ROUTER
1. Adjusting depth of cut (Fig. 3)
(1) Place the tool on a at wood surface.
(2) Turn the quick adjustment lever in a counterclockwise
direction until the quick adjustment lever stops. (Fig. 4)
(3) Turn the stopper block so that section to which the cutting
depth setting screw on a stopper block is not attached
comes to the bottom of the stopper pole. Loosen pole
lock knob allowing the stopper pole to contact with
stopper block.
(4) Loosen the lock lever and press the tool body until the bit
just touches the at surface. Tighten the lock lever at this
point. (Fig. 5)
(5) Tighten pole lock knob. Align the depth indicator with the
“0” graduation of scale.
(6) Loosen pole lock knob, and raise until indicator aligns
with the graduation representing the desired cutting
depth. Tighten pole lock knob.
(7) Loosen the lock lever and press the tool body down until
the stopper block to obtain the desired cutting depth.
Your router allows you to nely adjust depth of cut.
(1) Attach knob to ne adjustment knob. (Fig. 6)
(2) Turn the quick adjustment lever in a clockwise direction
until the quick adjustment lever stops with the stopper
screw. (Fig. 7)
If the quick adjustment lever does not stop with the
stopper screw, the bolt screw is not properly tted.
If this occurs, slightly loosen the lock lever and press
down on the unit (router) hard from the top and turn the
quick adjustment lever again after properly tting the bolt
screw.
(3) The depth of cut can be adjusted when the lock lever is
loosened, by turning the ne adjustment knob. Turning
the ne adjustment knob counterclockwise results in
shallower cut, whereas turning it clockwise results in a
deeper cut.
CAUTION
Ensure that the lock lever is tightened after nely
adjusting depth of cut. Failure to do so will result in
damage to the quick adjustment lever.
2. Stopper block (Fig. 8)
The 2 cut-depth setting screws attached to the stopper
block can be adjusted to simultaneously set 3 di erent
cutting depth. Use a wrench to tighten the nuts so that
the cut-depth setting screws do not come loose at this
time.
3. Guiding the router
WARNING
Be sure to switch power OFF and disconnect the plug
from the receptacle to avoid serious trouble.
(1) Template guide adapter
Loosen the 2 template guide adapter screws, so that the
template guide adapter can be moved. (Fig. 9)
Insert the centering gauge through the hole in the
template guide adapter and into the collet chuck.
(Fig. 10)
Tighten the collet chuck by hand.
Tighten the template guide adapter screws, and pull out
the centering gauge.
(2) Template guide
Use the template guide when employing a template
for producing a large quantity of identically shaped
products. (Fig. 11)
00BookM12V2.indb700BookM12V2.indb7 2022/12/2211:02:372022/12/2211:02:37
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hikoki M12V2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hikoki M12V2 in the language / languages: All languages as an attachment in your email.

The manual is 6.75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info