TROUBLESHOOTING
Use the inspections in the table below if the tool does not operate normally. If this does not remedy the problem, consult your
dealer or the HiKOKI Authorized Service Center.
1. Power tool
Symptom Possible cause Remedy
Tool doesn’t run No remaining battery power Charge the battery.
Battery isn’t fully installed. Push the battery in until you hear a click.
Tool suddenly stopped Tool was overburdened Get rid of the problem causing the
overburden.
Overload protection is in operation.
The battery is overheated. Let the battery cool down.
Cannot be inclined The incline lever (front) and incline wing nut
(rear) are not loosened. Try inclining after loosening the incline
lever (front) and incline wing nut (rear).
Tighten the loosened parts after making the
necessary adjustments.
Doesn’t cut well The saw blade is worn or missing teeth. Replace with a new saw blade.
The saw blade xing screw is loose. Firmly tighten the saw blade xing screw.
The saw blade is installed backwards. Install the saw blade in the proper direction.
Switch can’t be pulled The lock-o button is not pushed in enough. Push the lock-o button in all the way.
Sawdust discharge is poor Sawdust has accumulated in the saw cover. Remove the sawdust inside the saw cover.
Battery cannot be installed Attempting to install a battery other than that
speci ed for the tool. Please install a multi volt type battery.
2. Charger
Symptom Possible cause Remedy
The charge indicator lamp
is rapidly ickers purple,
and battery charging
doesn’t begin.
The battery is not inserted all the way. Insert the battery rmly.
There is foreign matter in the battery
terminal or where the battery is attached. Remove the foreign matter.
The charge indicator lamp
blinks red, and battery
charging doesn’t begin.
The battery is not inserted all the way. Insert the battery rmly.
The battery is overheated. If left alone, the battery will automatically
begin charging if its temperature decreases,
but this may reduce battery life. It is
recommended that the battery be cooled in
a well-ventilated location away from direct
sunlight before charging it.
Battery usage time is short
even though the battery is
fully charged.
The battery’s life is depleted. Replace the battery with a new one.
The battery takes a long
time to charge. The temperature of the battery, the charger,
or the surrounding environment is extremely
low.
Charge the battery indoors or in another
warmer environment.
The charger’s vents are blocked, causing its
internal components to overheat. Avoid blocking the vents.
The cooling fan is not running. Contact a HiKOKI Authorized Service
Center for repairs.
The USB power lamp
has switched o and the
USB device has stopped
charging.
The battery’s capacity has become low. Replace the battery with one that has
capacity remaining.
Plug the charger’s power plug into an
electric socket.
USB power lamp does not
switch o even though the
USB device has nished
charging.
The USB power lamp lights up green to
indicate that USB charging is possible. This is not a malfunction.
0000BookC3606DPA.indb190000BookC3606DPA.indb19 2022/12/1211:17:522022/12/1211:17:52
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hikoki C3606DPA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hikoki C3606DPA in the language / languages: All languages as an attachment in your email.

The manual is 9.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info