AMPLIFIER FEATURE DESCRIPTIONS
HFi AMPLIFIERS:
! Each model is capable of 4 & 2-Ohms stereo per channel, or 4-Ohms mono bridged operation ! All Hifonics amplifiers feature a comprehensive diagnostic system, with speaker lead short circuit,
and amplifier DC faults indicated by the red “PROTECT” LED.
except the mono amps which are capable of 4, 2 and 1-Ohm loads.
CAUTION: DO NOT OPERATE ANY AMPLIFIER BELOW THE INTENDED IMPEDANCE. YOU
Tri-Mode operation with any stereo pair of amplifier channels is possible, as with all bridgeable
!
!
WILL CAUSE DAMAGE TO THE AMPLIFIER THAT WILL NOT BE COVERED UNDER THE
amplifiers.
! The input sensitivities for rated output powers are variable from 0.2 volts to 6 volts.
WARRANTY PRINTED IN THE BACK OF THE MANUAL. 2 & 4 Channel amps are capable of 4
! All crossovers are fully variable in their respective ranges.
and 2-Ohms wired stereo and 4-Ohms wired mono bridged. The mono amps are capable of 4, 2
! Crossover filters are 12dB/Octave.
and 1-Ohm.
! A POWER LED indicates the powered up and turned on condition.
2
-The LINE INPUT signal is routed directly to the LINE OUT RCA jacks, regardless of the X-OVER
setting simplifying daisy chaining of amplifiers.
-SUBSONIC: Allows you to adjust the crossover filter from 15Hz to 35Hz.
-LPF: Allows yo to adjust the LOW PASS crossover filter from 30Hz to 250Hz.
LEVEL: Adjusts the input sensitivity from 0.2 volts to 6 volts.
BASS EQ: The Bass EQ is adjustable from 0db to 10dB.
REMOTE: This is the input jack for the remote Level control.
LINE INPUT: The line input accepts unbalanced (RCA) inputs from 0.2V to 6V.
LINE OUTPUT: The line output passes through signal from the line inputs which allows you to daisy
chain multiple amplifiers from one signal.
The mono amps are capable of 4, 2 & 1-Ohm loads.
Operating the amp below 1-Ohm can cause damage to the
amp not covered in the warranty.
HFi1000D / HFi1500D / HFi2000D / HFi2500D MONO BLOCK AMPLIFIERS
OUTPUT INPUT
L L
R R
POWER
PROTECT
6V 0.2V 0dB 10dB 15Hz 35Hz 30Hz 250Hz
LEVEL BASS EQ REMOTE SUBSONIC LOW PASS
The 4 channel amps have the same features as the 2 channel models accept that there are 2 sets of
controls.
1 set for channels 1 & 2 and 1 set for channels 3 & 4.
In addition, the 4 channel models have a Mode switch which allows you to select 2, 3 or 4 channel
operation. Switch to 2 channel if you only have 1 set of RCA’s in CH 1/2 and the unit will automatically
supply signal to channels 3/4. Select 3 channel when you only have RCA’s in CH 1/2 but plan to run
channels 3/4 bridged. Select 4 channel if you are providing RCA’s to channels 1/2 and 3/4.
The X-OVER slide switch selects the internal crossover functions:
-The input signal is routed directly to the LINE OUT RCA jacks, regardless of the X-OVER setting
simplifying daisy chaining of amplifiers.
-HPF: Selects the built in HIGH PASS filter, variable from 60 Hz to 12kHz.
-FULL: Bypasses all crossovers for full frequency range operation.
-LPF: Selects the built in LOW PASS , variable from 30 Hz to 250Hz.
MODE: The mode switch allows you to choose Stereo for full range 2 channel operation or MONO
for bridging operation
HIGH INPUT: If your radio/CD player does not have unbalanced (RCA) outputs, you can use the
HIGH level (wire) inputs.
LINE INPUT: The line input accepts unbalanced (RCA) inputs from 0.2V to 6V.
LINE OUTPUT: The line output passes through signal from the line inputs which allows you to daisy
chain multiple amplifiers from one signal.
Note that the LOW PASS signal is MONO.
-In the LPF position, the HIGH PASS filter acts as a subsonic
filter.
-When the LPF mode is selected, a 0 to +12dB, at 45Hz, BASS
-EQ is also switched in.
HFi55.4 / HFi100.4 4-CHANNEL AMPLIFIERS
LINE OUTCH3/4 CH1/2
L L
R R
6V 0.2V 0dB 12dB FULL LPF HPF 60Hz 12KHz 30Hz 250Hz
LEVEL BASS EQ X-OVER HPF LPF
6V 0.2V 0dB 12dB FULL LPF HPF 60Hz 12KHz 30Hz 250Hz 2 3 4
LEVEL BASS EQ X-OVER HPF LPF MODE
POWER
PROTECT
The X-OVER slide switch selects the internal crossover functions:
-The input signal is routed directly to the LINE OUT RCA jacks, regardless of the X-OVER setting
simplifying daisy chaining of amplifiers.
-HPF: Selects the built in HIGH PASS filter, variable from 60 Hz to 12kHz.
-FULL: Bypasses all crossovers for full frequency range operation.
-LPF: Selects the built in LOW PASS , variable from 30 Hz to 250Hz.
MODE: The mode switch allows you to choose Stereo for full range 2 channel operation or MONO
for bridging operation
HIGH INPUT: If your radio/CD player does not have unbalanced (RCA) outputs, you can use the
HIGH level (wire) inputs.
LINE INPUT: The line input accepts unbalanced (RCA) inputs from 0.2V to 6V.
LINE OUTPUT: The line output passes through signal from the line inputs which allows you to daisy
chain multiple amplifiers from one signal.
Note that the LOW PASS signal is MONO.
-In the LPF position, the HIGH PASS filter acts as a subsonic
filter.
-When the LPF mode is selected, a 0 to +12dB, at 45Hz, BASS
-EQ is also switched in.
HFi100.2 2-CHANNEL AMPLIFIERS
OUTPUT INPUT
L L
R R
6V 0.2V 0dB 12dB FULL LPF HPF 60Hz 12KHz 30Hz 250Hz MONO STEREO
LEVEL BASS EQ X-OVER HPF LPF MODE
POWER
PROTECT
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hifonics HFi at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hifonics HFi in the language / languages: English as an attachment in your email.

The manual is 3,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info