BOXER / MARLIN / FALCON / POLAR SERIES USER MANUAL
Version 06.03 DIG.EN 13
MACHINE CONTROL PANEL
CONTROL PANEL VERSIONS
General
The digital control panels are implemented with 9 pre-select programs that can be individually
set with different function values (to be able to pack different products) Program 0 can not be
set and is used for servicing and testing. A program cycle is the complete program of set
functions that the machine runs through to package a product.
The control panels are designed with a operation mode and a program mode.
The operation mode is used during operational activities for selecting the program number
with the required program cycle. The set values of the function program can also be seen in
the operation mode but not changed.
The program mode is used to change the function values within the programs.
The control panels are implemented standard with an automatic conditioning program for the
regular maintenance of the pump and two STOP keys for complete cycle interruption or for
only active function interruption. There are also a number of built-in service programs. Contact
the supplier or Henkelman BV for more information about these programs.
Digital Time Control
The value of all active functions can be set for a certain time period.
The vacuum function, gas flush function (if installed), and soft air function can be set in whole
seconds up to a maximum of 99 seconds.
The seal function can be set with an interval of 0.1 seconds and a maximum of 6.0 seconds.
Digital Sensor Control
The value of the vacuum function and the gas flush function (if installed) can be set as a
percentage of the vacuum. This is the percentage of the under pressure in the vacuum
chamber related to the outside pressure 1 atmosphere/ATO (0%).
The maximum vacuum percentage setting of the vacuum function is 99%.
The minimum vacuum percentage setting of the gas flush function is 30%. This means that
the chamber is flushed with gas to 30% under pressure in relation to 1 atmosphere. It is often
expressed as 70% is flushed with gas (99+% - 30% = 70%).
The time for the soft air function can be set on whole seconds (max. 99 seconds).
The time for the seal function can be set on 0.1 seconds (max. 6.0 seconds).
The digital sensor control comes standard with the VACUUM PLUS function. The VACUUM
PLUS function is a time operated additional vacuum function for setting extra time after
reaching the 99% value of the vacuum function (only applicable if 99% is set for the vacuum
function). This function provides additional vacuum time for vacuuming any trapped air out of
the package.
Contact the supplier or Henkelman BV for information about special operating panels not shown above.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Henkelman MARLIN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Henkelman MARLIN in the language / languages: English as an attachment in your email.

The manual is 4,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Henkelman MARLIN

Henkelman MARLIN User Manual - German - 44 pages

Henkelman MARLIN User Manual - Dutch - 43 pages

Henkelman MARLIN User Manual - French - 46 pages

Henkelman MARLIN User Manual - Spanish - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info