647370
44
Zoom out
Zoom in
Previous page
1/48
Next page
44
Electrical index Lynx 32, (1)
Control diagram
002-PCB
Main circuit diagram
011
Machine serie
Lynx 32
Revision (from-Untill)
Power (V/~/Hz)
230-1-50
Seal configuration
Front
Pomp capacity
008 M
3
/h
Seal type
Double / Cut-off
Main electrical supply:
L1 Phase 1
N Neutral
PE Ground connection
Overload devices:
Fuse main entrance F1, F2 Part number: 0232014
Specification: 10 Amp. Slow
Size: 5 x 20 mm
Fuse seal transformer F4 Part number: 0232027
Specification: 3,15 Amp. Slow
Size: 5 x 20 mm
Fuse control transformer F6 Part number: 0232016
Specification: 0,5 Amp. Slow
Size: 5 x 20 mm
F7 Part number: 0232017
Specification: 2,5 Amp. Slow
Size: 5 x 20 mm
Fuse PCB F8 Part number: 0232014000
Pump:
Pump type
8 M
3
/h
Capacity 0,35 kW
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Henkelman Lynx 42 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Henkelman Lynx 42 in the language / languages: English as an attachment in your email.

The manual is 3,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Henkelman Lynx 42

Henkelman Lynx 42 User Manual - German - 56 pages

Henkelman Lynx 42 User Manual - Dutch - 50 pages

Henkelman Lynx 42 User Manual - French - 49 pages

Henkelman Lynx 42 User Manual - Spanish - 49 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info