STANDARD MAINTENANCE SCHEDULE FOR THE MACHINE
Daily
Clean the vacuum chamber, lid, and housing after use with a damp cloth.
Make sure that no cleaning agents containing solvents are used.
Make sure that no high pressure cleaner is used.
Weekly
Check the oil level and replace or fill up oil when the oil is turbid or the oil level is too
low. For instructions, see page 23.
Activate the conditioning program for the pump at least once a week.
Inspect the sealing bar for damage. Replace teflon tape/sealing wire if the seal quality
is no longer sufficient or if the teflon tape/sealing wire is no longer tight and straight on
the sealing bar. For instructions, see page 26.
Inspect the lid gasket and replace it when the gasket is damaged or stretched. For
instructions, see page 27.
Inspect the transparent lid (if applicable). When cracks are visible, turn off the machine
immediately and contact the supplier or Henkelman BV.
Every Six Months
Replace oil at least once every 6 months.
Yearly
Inspect the oil exhaust filter for saturation. If saturated, replace the filter. For
instructions, see page 24.
Contact the supplier for a professional service
Four-yearly
Replace transparent lid and the lid’s gas springs (if applicable)
Replace membranes sealcylinder (if applicable)
VACUUM PUMP MAINTENANCE
It is very important to regularly service the pump to ensure extended and correct operation. The following activities are
essential for correct maintenance. If the machine is used regularly then it is advisable to have the pump fully inspected at
least once a year by the supplier to ensure extended and problem free operation. Contact the supplier or Henkelman BV
for more advice and information.
Conditioning Program
The conditioning program ensures that the pump is thoroughly rinsed. During the program the pump and oil
reaches operation temperature so that the oil can better absorb any moisture and contaminants and filter them. The high
temperature enables any moisture in the pump to evaporate minimising the risk for rust spots.
The program lasts 15 minutes and it is advisable to run it at least once a week. Turn on the machine, press the key
[conditioning program], and close the lid. The program runs automatically. During the program the large display will
display moving lines.
The program can be interrupted at any time using the [STOP] key. It is however important for the sake of good
maintenance that the program completes a full 15 minute cycle and therefore advisable only to interrupt the cycle for
something urgent.
It is also advisable to run the program before using the machine for the first time, after the machine has been stationary
for a lengthy period of time, and especially prior to changing oil.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Henkelman FALCON at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Henkelman FALCON in the language / languages: English as an attachment in your email.

The manual is 4,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Henkelman FALCON

Henkelman FALCON User Manual - German - 44 pages

Henkelman FALCON User Manual - Dutch - 43 pages

Henkelman FALCON User Manual - French - 46 pages

Henkelman FALCON User Manual - Spanish - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info