741200
9
Zoom out
Zoom in
Previous page
1/15
Next page
_ Hob _ rev. 0 _____________________________________________________________________ KP 96 – KTP 96 _
_ CATEGORY II2H3+ _ GB __
0705
______________________________________________________ page 9 _
Residual risks
- Keep away from the appliance unskilled personel.
- The appliance contains electrical parts and must never be washed with a jet of water or steam.
- To avoid wrong installation, the right gas connection is showed on a label that identifies the correct
gas type to use.
- The appliance is electrically connected: before attempting any cleaning operation, cut power to the
appliance.
- The removable parts of the cooking top, after the cleaning operation, must be placed correctly in
their housing in order to avoid anomalous and dangerous functioning of the burners.
4. Gas connection
Connect the appliance to a gas cylinder or mains gas pipe according to the prescriptions of
standards (as per current national installation norms and subsequent amendments). To connect gas,
use an approved rigid metal pipe in copper or stainless-steel (the current national installation norms
and subsequent amendments). The appliance is equipped with threaded GJ ½” pipes for gas inflow.
Check if the appliance is designed to operate on the same type of gas as supplied and if pressure is set
for that type of gas. Otherwise, carry out the operations indicated in paragraph “ADAPTING TO
DIFFERENT TYPES OF GAS”.
IMPORTANT - Make sure that supply pressure matches the values indicated in the table “Burner
and nozzle characteristics” (tab.1).
If supply pressures do not match the values in the table, eliminate the cause of this, or inform the
gas company and do not use the appliance. Connection with rigid or flexible metal pipes must not
cause stresses to the appliance pipe (“train”).
5. Electric connection
Before performing the electric connection, make sure that:
- the relief valve and the system can stand the appliance load (see data on the rating plate);
- THE SUPPLY SYSTEM IS EQUIPPED WITH AN APPROPRIATE GROUND CONNECTION IN
ACCORDANCE WITH THE REGULATIONS IN FORCE;
- the omnipolar system used for the connection can be easily reached with the appliance installed.
In the grid-connected mode, between the appliance and the grid an omnipolar switch must be
inserted, having a 3 mm minimum opening between contacts, suitable to the load used and in
accordance with the regulations in force. The yellow/green earth cable must not be interrupted by
the switch.
The appliance must be connected to an equipotential system whose efficiency must first be checked
according to current legal regulations. When the appliance is operating, the supplied voltage must not
deviate from the nominal voltage value of ±10%.
If the power cable needs replacing, it must be secured through the cable gripper and must have the
following characteristics:
- type (HAR) H07RN-F with three conductors
- minimum diameter: 0.75 mm
2
.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hendi KTP 96 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hendi KTP 96 in the language / languages: English as an attachment in your email.

The manual is 0,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info