741187
11
Zoom out
Zoom in
Previous page
1/26
Next page
_ Electric Cookers _ rev. 1 ______________________ KCP96 V – KCP96 VS – KCP5 96 V – KCP5 96 VS – KC 96 V –
KC 96 VS – KC 96 M – KC 96 MS – KCR 96 V _
_ CATEGORY II2H3+ _ GB __
0705
_____________________________________________________ page 11 _
6. Adapting cook-top to different types of gas
Mod. KCP96 V – KCP96 VS – KCP5 96 V – KCP5 96 VS
To adapt the hob to a type of gas that differs
from the one tested in the factory (see data plate
or supplementary plate), replace the nozzles of
the five burners Remove the pan carrier grilles
from the hob and withdraw the movable parts of
the burners from their seats:
- Remove the pot support grids from the
cook-top and remove the mobile parts of
the burners from their position.
- Unscrew the jets (Fig. 2) using the 7 mm.
Key and replace them with the new ones
(see table 1). Check the exact
correspondence of the diameter indicated
on the table with that printed on the jets.
After having replaced the jets, set up all the
parts again and stick the new data on the
technical data plate.
Fig. 2
N.B. The burners don’t need any air regulation.
Minimum level adjustment - Burner minimum levels are preset for methane gas (G20)
operation. If operating on liquid gas (G30/G31) proceed as follows: ignite the burner at
minimum position, and, using a screwdriver, fully tighten the by-pass adjustment screw at the
side of the shank of the relevant tap. Check if the flame remains stable and uniform – to help
you check, rapidly turn the tap knob from maximum to minimum position. When you have
finished adjusting the by-pass valve, seal it with red paint. Make sure you fit a plate with the
new installation data. After having set the by-pass screw, seal it with red varnish.
Gas pressure (mbar)
Type of gas Normal Max. Min.
Table 1
G30 30 35 20
G31 37 45 25
G20 20 25 17
Main nozzles diameter
(1/100 mm)
By-pass screw nozzles
diameter
(1/100 mm)
Consumption calculated with gross
heat values
Nominal
thermal
capacity
(kW)
Reduced
thermal
capacity
(kW)
G30/G31
30/37mbar
G20
20mbar
G30/G31
30/37mbar
G20
20mbar
G30
30mbar
(g/h)
G31
37mbar
(g/h)
G20
20mbar
(l/h)
Triple crown
burner Nr. 1
3.5 1.8 95 135 74 Regul. 255 250 334
Fast burner
Nr. 3
3 0.95 85 115 50 Regul. 218 214 286
Semi-fast burner
Nr. 1
1.75 0.6 65 97 40 Regul. 127 125 167
Mod. KC 96 V – KC 96 VS – KC 96 M – KC 96 MS – KCR 96 V
To adapt the cook-top to a different type of gas from the one used to test the device in the
factory (see data plate or supplementary plate), replace the nozzles of the five burners and set
the primary air flow by means of the appropriate tools. To do so it will be necessary to
disassemble the cooker cook-top in order to easily access the burners, the nozzle holders and
the tools used to adjust the primary air. Proceed as follows:
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hendi KCP 96 V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hendi KCP 96 V in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hendi KCP 96 V

Hendi KCP 96 V User Manual - German - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info