742455
124
Zoom out
Zoom in
Previous page
1/128
Next page
124
GR
Symbol Name Type Mode Meaning
Up/Switch Button
Press and hold for min.
3 seconds Switch ON/OFF
Press and release Scrolling functions; increasing the value of the se-
lected parameter (In the programming mode)
Down/
Defrosting Button
Press and hold for min.
3 seconds Manual defrosting will start
Press and release Scrolling functions; decreasing the value of the se-
lected parameter (In the programming mode)
Set/Mute Button
Press and release Mutes the audible alarm
Press and hold for min.
1 second Displays/sets the set point
Press and hold for min.
3 seconds Accesses the parameter setting menu
Aux Light Illuminated The additional output active (service mode only)
Clock (RTC) Light Illuminated RTC available, enabled (tEN=1) and at least one
time band has been set (service mode only).
Alarm Light Illuminated Alarm in progress
Cooling
Fan Light
Illuminated Fan activated
Blinks The start of fan is delayed due to external shut-off;
other procedure is in progress
Defrosting Light
Illuminated Defrosting in progress
Blinks The start of defrosting is delayed due to external
shut-off; other procedure is in progress
Compresor Light
Illuminated Compressor on
Blinks The start of Compresor is delayed by protective
procedure
Operation of control panel
Changing the set value
In order to display the set value, press and imme-
diately release the [SET/MUTE] button.
Press and hold the [SET/MUTE] button for at least
1 seconds to change the set value. The current
set value will be displayed.
To change the set value, press the [UP/SWITCH]
or [DOWN/DEFROSTING] arrows. To store the
new set value, press the [SET/MUTE] button
again or wait 15 seconds.
Setting the default parameters
To reset the default parameters:
disconnect power from the instrument;
reconnect power while holding the [SET/MUTE]
and [DOWN/DEFROSTING] buttons;
the display will show the message “CF”;
after a few seconds the instrument starts oper-
ating with the default configuration. Any different
parameter settings will need to be updated.
Warnings: running this procedure overwrites any
custom parameter settings.
124


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hendi 232873 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hendi 232873 in the language / languages: English, German, Dutch, French, Italian, Polish as an attachment in your email.

The manual is 1,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info