741201
7
Zoom out
Zoom in
Previous page
1/40
Next page
INSTALLATION
GENERAL INSTRUCTION
The appliance described in this manual has been built to meet 2014/35/EU (Safety), 2014/30/EU (EMC), Re 2016/426/EU
(GAR), Re 1935/2004/EC, Re 2023/2006/EC directives; and UNI EN 203…, UNI EN 437, EN 60335-1, EN60335-2-36 and
EN55014 standards. This appliance has been designed exclusively for cooking food, any other use is considered improper: be
careful that no live animal, person or “dangerous” objects are placed inside the oven. It should only be used by qualified
personnel in professional kitchens. Materials in contact with foodstuffs are suitable for use. The unit must never be left
unattended when it is being used! The appliance should be checked once a year by a qualified technician. Switch the appliance
off in the case of a failure or malfunction.
The appliance should be installed under an extractor hood for removing any cooking fumes.
Care must be taken when using the appliance because the cooking surfaces are very hot. The appliance must be
installed, connected and serviced properly by qualified personnel according to the regulations and directives in force in
the country where it is installed, as well as the instructions in this manual.
UNIT CHARACTERISTICS
These installation and user's instructions refer to the category II2H3+ gas ranges. The data plate is outside the back panel to
the appliance. The supplementary plate is also made of self-adhesive polyester and is affixed near the data plate; it contains all
information regarding the appliance. The gas distribution network fitting fig.1 meets ISO 7/1 and ISO 228/1 standards with a ø
½” connection, situated at the back of the machine. The structure of the appliance is made of stainless steel, the burners are
made of cast iron and the oven is made of stainless steel. All models have adjustable feet. The main gas pipe is made of
galvanized steel. The pipes between the tap and burner are made of copper.
Install a shut-off cock in the line between the appliance and the gas distribution network. Install an omnipolar switch
between the appliance and the electrical distribution network.
CONNECTION TO THE GAS DISTRIBUTION NETWORK
Before you install the appliance, make sure that the gas company has authorised the installation, compare the
data relevant of the appliance (data plate) with the local supply.
Remove the packaging from the appliance as well as the protective plastic sheet, and, if necessary, remove traces of glue with
a suitable solvent. To dispose of the packaging, follow local directives (for more details refer to the chapter “ECOLOGY AND
THE ENVIRONMENT”. Prior to connecting the unit to the gas network, check the data plate to see if the unit has been set and
tested for the type of gas supplied. If the gas type indicated on the data plate is not the same as that supplied, please refer to
the paragraph CONVERSION AND ADAPTATION”. Connect the appliance to the gas distribution network using metal pipes
with a suitable diameter; install a homologated shut-off cock between the appliance and the distribution network. If flexible pipes
are used, they must be made of stainless steel according to the standards in force. When installing the appliance, all the
regulations in force must be observed, such as:
Installation and safety standards in force.
Regional and/or local regulations, such as building codes.
Directives and regulations of the electricity board.
Accident prevention regulations in force.
Fire prevention regulations.
Applicable I.E.C. regulations.
We recommend installing the appliance in a well-ventilated environment, or under an extraction hood to remove the fumes or
vapors produced during the cooking cycle. All models have an equipotential earth terminal fig.1 in the bottom. The appliances
with an electric oven have a hole for the cable fig.1. The appliance can be installed alone or in line. Respect a minimum
distance of 80mm between the appliance and any walls made of flammable material, partitions, kitchen furniture or nearby
equipment. The contact surfaces must be covered with non-combustible heat insulating material. The appliance, and especially
the power lead, must not be installed anywhere near heat sources and the temperature of the place in which the appliance is
installed must not rise above 50°C. After installing the appliance check for any leaks in the fittings. Use non-corrosive foam
products, such as leak detection sprays, to look for any leaks.
When checking for leaks do not use naked flames!
The manufacturer shall not be held responsible and the guarantee is void in the case of damage caused by negligence
in following the operating and installation instructions or by improper use. The guarantee is void in the case of
connections which have been made in a way which doesn't meet the current standards and fire-fighting regulations.
EVACUATION OF BURNT GASES: A1 APPLIANCE
Appliances must be installed under an extraction hood with forced draught, subjected to gas supply.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hendi 225882 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hendi 225882 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 4,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info