801919
21
Zoom out
Zoom in
Previous page
1/192
Next page
USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS
20 Pump
2.5 Connecting external digital inputs
CAUTION: Before carrying out any electrical work on the pump, unplug the power cord and wait 5 min.
The filtration pump is equipped with a 3-m long 5-wire cord for connecting the 4 digital inputs or potential-free dry contacts
(Open/Closed).
Examples of digital inputs
Assign the speed and flow required for the peripheral devices, such as a heat pump, roller blind or robotic vacuum, etc.
to work properly.
Install a user interface control unit. These digital inputs are used to control, from a distance of 3 m, the Run/Stop
function as well as the 3 speeds (V1-V2-V3).
Assigning the wires DI1
DI2
DI3
DI4
C
3 m
DI1 Brown Speed V1
DI2 Green Speed V2
DI3 White Speed V3
DI4 Red Run/Stop
CBlack Common
N.B.
If the digital inputs are partially used, electrically insulate the unused wires.
If the digital inputs are unused, insert the connector (A) instead of the 5-wire cord (see figure below).
A
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward TriStar VSTD Pump at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward TriStar VSTD Pump in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 27.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info