ПРИМЕЧАНИЯ
PS : ДАТЧИК ДАВЛЕНИЯ EEV : ЭЛЕКТРОННЫЙ РЕДУКТОР
AT : ДАТЧИК ТЕМПЕРАТУРЫ ВОЗДУХА FM1 : МОТОР ВЕНТИЛЯТОРА DC
OT : ДАТЧИК ТЕМПЕРАТУРЫ ВОДЫ НА ВЫХОДЕ HP : ПРЕССОСТАТ ВЫСОКОГО ДАВЛЕНИЯ
SUT : ДАТЧИК ТЕМПЕРАТУРЫ ВСАСЫВАНИЯ OHP : ТЕПЛОВАЯ ЗАЩИТА
LP : ПРЕССОСТАТ НИЗКОГО ДАВЛЕНИЯ 4V : 4-Х КАНАЛЬНЫЙ ВЕНТИЛЬ
FS : ДЕТЕКТОР НАЛИЧИЯ ВОДЫ K2 : СВОБОДНЫЙ КОНТАКТ С МАКСИМАЛЬНЫМ
ПОТЕНЦИАЛОМ 7 А
IT : ДАТЧИК ТЕМПЕРАТУРЫ ВОДЫ НА ВХОДЕ PTC : ТЕРМИСТОР
CT : ДАТЧИК ТЕМПЕРАТУРЫ ИСПАРИТЕЛЯ KM1 : КОНТАКТОР КОМПРЕССОРА
ET : ДАТЧИК ТЕМПЕРАТУРЫ НАГНЕТАНИЯ COMP : КОМПРЕССОР
N
13
2 4
5
6
7
8
01
N
L
N
NN
N
N
4V
13
2 4
5
6
7
8
02
N
L
Y/G
YEL
L
N
RED
BLU
A
GND
12V
B
P1
W UV P2 PE ACN ACL L1 L2
CN614
CN617
CN618
CN604 CN608CN607
P1
P2
L4
N
U
V
W
COMP
UVW
UW
V
REDBLK WHT
PTC
K2
N
N
N
13
2 4
5
6
7
8
03
L4
L4
-T
L4
L
P2
L
N
KM1
L
N
N
K2
N
N
N
LL
ACL-out
ACN-outACN-in
ACL-in
CN1
FM1
N
GND
485A1
12V
N
L485B1
Y/G
WHT
BLK
CN4
L
L
4V
4
1
RED
BLK
WHT
Pressure sensor
(PS)
CN9
3
RLY1
OUT2
OUT3
AC-N1
OUT4
OUT5
CN2
CN8
4
CN13
A1A3A5A7A9
A11
t
5K
SUT LP
A4A6A8A10
A12 A2
FS
t
5K
IT
t
5K
CTET
t
50K
t
5K
OT
t
5K
AT
6.8K
CN11
A13
GND
GND
GND
GND
+12V
0~10V-OUT
PWM-IN
PWM-OUT
5V
5V
L
L
KM1
EEV
5
P2
L4
L
L
N
N
L
NN
1
POWER SUPPLY
220-240V~/50Hz
4
electric reactor
HP
HP
OHP
HP
OHP
5 6 7 8
OHP
5
8
58
4
WHT 485A+
YEL 485B-
RED 12V
Controller
BLK GND
WiFi
WHT 485A+
YEL 485B-
RED 12V
BLK GND
LN
K2
12
1
2
3 4
3
4
34
Remote
ON/OFF
connection
Dry Contact
7 A max
CPS Drive Board
Fan Driver Board
Main Board
6. ПРИЛОЖЕНИЯ (продолжение)
HP5211DT3 / HP5251DT3
к источнику
питания
220-240V/50Hz
397


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward SumHeat Fi Heat Pump - R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward SumHeat Fi Heat Pump - R32 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 28.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info