801934
215
Zoom out
Zoom in
Previous page
1/418
Next page
27
R
S
T
N
RED
BLK
WHT
BLU
R S TN
R
N
4V
13
2 4
5
6
7
8
02 N
N
N
N
N
N
K2
4V
N
R
13
2 4
5
6
7
8
01 R
R
4
1
RED
BLK
WHT
Pressure sensor
(PS)
Y/G
COMP
UV
W
U
V
W
K2
24
DCN-IN
U V WR S T
DCP-IN
DCN-OUT
DCP-OUT
B
A
GND
12V
CN602
GND
CN605
5V
JP601
electric reactor
R
S
T
RED
BLK
WHT
R
S
T
N
N
2
R
DC+
DC1+
DC-
DC1-
EEV
5
CN9
3
RLY1
OUT2
OUT3
AC-N1
OUT4
OUT5
CN2
CN8
4
A1A3A5A7A9
A11
t
5K
SUT LP
A4A6A8A10
A12 A2
FS
t
5K
IT
t
5K
CT
ET
t
50K
t
5K
OT
t
5K
AT
6.8K
CN11
A13
GND
GND
GND
GND
+12V
0~10V-OUT
PWM-IN
PWM-OUT
2
5V
5V
A- B- C- N-
NCBA
EMI
FI
4
To power supply
380-415V/3N~/50Hz
CN1
FM1
R
N
GND
485A1
12V
N
L485B1
Y/G
WHT
BLK
CN4 YEL
1
CN13
LN
R
N
N14
8
5
4
WHT 485A+
YEL 485B-
RED 12V
Controller
BLK GND
WiFi
WHT 485A+
YEL 485B-
RED 12V
BLK GND
HP
HP
OHP
HP
OHP
5 6 7 8
OHP
58
Remote
ON/OFF
K2
12
1
2
3 4
34
Dry Contact
7 A max.
3
4
N
Fan Driver Board
CPS Driver Board
Main Board
6. ANHANG (Fortsetzung)
Allgemeine
Stromversorgung
380-415V/3N / 50Hz
HP5211ET3 / HP5251ET3
LEGENDE
PS : DRUCKSENSOR ET : DRUCKTEMPERATURSONDE
AT : AUSSENTEMPERATURSENSOR EEV : ELEKTRONISCHER SENSOR
OT : SENSOR DER TEMPERATUR DES WASSERAUSLASSES FM1 : MOTOR VENTILATOR DC
SUT : SENSOR DER SAUGTEMPERATUR HP : HOCHDRUCKREGLER
LP : NIEDRIGDRUCKREGLER OHP : HITZESCHUTZ
FS : SENSOR DES WASSERSTANDES 4V : 4-WEGE-VENTIL
IT : SENSOR DER TEMPERATUR DES WASSEREINLASSES K2 :
POTENTIALFREIER TROCKENKONTAKT MAX. 7 A
CT : TEMPERATURSENSOR DES EVAPORATORS COMP : KOMPRESSOR
215


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward SumHeat Fi Heat Pump - R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward SumHeat Fi Heat Pump - R32 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 28.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info