(a) Aire seco 27°C - Humedad relativa 78% - Temperatura de entrada del agua 26°C.
(b) Aire seco 15°C - Humedad relativa 71% - Temperatura de entrada del agua 26°C.
2. CARACTERÍSTICAS TÉCNICAS (continuación)
Modelos
SUMHEAT
Full Inverter
HP5211ET3 HP5251ET3 HP5301ET3
Tensión de alimentación V / Ph / Hz 380 V - 415 V / 3 ph / 50 Hz
Refrigerante Type HFC - R32 - (CH2F2)
Grupo de seguridad Type A2L
Carga kg 1,35 1,65 1,8
Masa en tCO2eq teqCO20,91 1,11 1,22
Frecuencia de control de fuga /Ninguna exigencia, pero se recomienda una vez al año
Capacidad de calentamiento Mín--Máx (a) kW 6,24 -- 22,10 6,02 -- 24,50 8,12 -- 31,20
Potencia eléctrica absorbida Mín--Máx (a)
kW 0,46 -- 3,07 0,41 -- 3,67 0,59 -- 5,08
Corriente nominal de servicio Mín--Máx (a) A1,00 -- 5,10 0,90 -- 5,81 1,21 -- 8,23
COP Máx--Mín (a) /13,70 -- 7,19 14,53 -- 6,68 13,72 -- 6,14
Capacidad de calentamiento Mín--Máx (b) kW 4,84 -- 16,92 4,55 -- 19,55 5,52 -- 23,05
Potencia eléctrica absorbida Mín--Máx (b)
kW 0,68 -- 3,10 0,63 -- 3,68 0,79 -- 4,94
COP Máx--Mín (b) /7,10 -- 5,46 7,18 -- 6,42 6,98 -- 4,66
Corriente máxima de servicio (CMS) A 8,7 11,7 13,3
Calibre del fusible aM 10 12 16
Disyuntor curva D D 10 12 16
Intensidad por arranque A< CMS
Conexión hidráulica mm 50 mm
Caudal nominal de agua (a) m3/h 9,1 10,5 12,6
Pérdida de carga máxima en el agua kPa 17 15 46
Compresor / Panasonic Panasonic Mitsubishi
Tipo / Rotativo doble
Cantidad / 1
Resistencia de enrollado a 20°C Ohm 0,88 0,88 0,49
Ventilador / Axial
Cantidad 1
Diámetro mm 560 560 600
Cantidad de aletas / 3
Motor / DC Inverter
Cantidad / 1
Velocidad de rotación Tr/min 500 -- 700 600 -- 750 500 -- 700
Velocidad modo silencio Tr/min 500 400 400
Nivel de presión acústica a 1 m dB(A) 56,4 -- 61 55,2 -- 59,7 55,6 -- 59,3
Nivel de presión acústica a 10m dB(A) 40,9 -- 45,4 40,9 -- 44,2 36,1 -- 42,2
Dimensiones netas de la unidad (longitud-
ancho-altura) mm 797 x 777 x 965 846 x 920 x 1024
Masa kg 101 101 123
101


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward SumHeat Fi Heat Pump - R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward SumHeat Fi Heat Pump - R32 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 28.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info