5. MAINTENANCE AND WINTERISING
5.1 Maintenance
These maintenance operations must be carried out once per year in order to
guarantee the longevity and the good working condition of the heat pump.
Clean the coil with the help of a soft brush or jet of air or water (Warning,
never use a high pressure cleaner).
Verify that the drains flow well.
Verify the tightening of the hydraulic and electrical connections
Verify the hydraulic sealing of the condenser.
Have the leak-tightness of the cooling circuit to the leak detector checked
by an accredited professional.
Before any maintenance operation, the heating pump must be
disconnected from any electrical current source. The maintenance
operations must only be carried out by personnel that is qualified and
authorised to handle liquid refrigerants.
Any damage caused by poor winterising maintenance will lead to
cancellation of the warranty.
5.2 Winterising
Put the heat pump in “OFF” mode.
Cut the power supply to the heat pump.
Drain the condenser to avoid it being damaged by frost during the winter.
To do so, dismantle the water inlet and outlet couplings.
Close the by-pass valve and unscrew the entry/exit connection unions.
Eliminate the maximum amount of residual stagnant water from the
condenser with the help of an air gun.
Close the water entry and exit areas of the heating pump to avoid
introducing foreign bodies.
Cover the heating pump with a dedicated winterising case.
73


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward SumHeat Fi Heat Pump - R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward SumHeat Fi Heat Pump - R32 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 28.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info