(a) Air sec 27°C - Humidité relative 78% - Température d'entrée d'eau 26°C.
(b) Air sec 15°C - Humidité relative 71% - Température d'entrée d'eau 26°C
Modèles SUMHEAT
Full Inverter HP5211ET3 HP5251ET3 HP5301ET3
Tension d'alimentation V / Ph / Hz 380 V - 415 V / 3 ph / 50 Hz
Réfrigérant Type HFC - R32 - (CH2F2)
Groupe de sécurité Type A2L
Charge kg 1,35 1,65 1,8
Masse en teqCO2teqCO20,91 1,11 1,22
Fréquence du contrôle de fuite /Aucune exigence mais conseillé de façon annuelle
Capacité de chauffage Min--Max (a) kW 6,24 -- 22,10 6,02 -- 24,50 8,12 -- 31,20
Puissance électrique absorbée Min--Max
(a) kW 0,46 -- 3,07 0,41 -- 3,67 0,59 -- 5,08
Courant nominal de service Min--Max
(a) A1,00 -- 5,10 0,90 -- 5,81 1,21 -- 8,23
COP Max--Min (a) /13,70 -- 7,19 14,53 -- 6,68 13,72 -- 6,14
Capacité de chauffage Min--Max (b) kW 4,84 -- 16,92 4,55 -- 19,55 5,52 -- 23,05
Puissance électrique absorbée Min--Max
(b) kW 0,68 -- 3,10 0,63 -- 3,68 0,79 -- 4,94
COP Max--Min (b) /7,10 -- 5,46 7,18 -- 6,42 6,98 -- 4,66
Courant maximum de service (CMS) A 8,7 11,7 13,3
Calibre du fusible aM 10 12 16
Disjoncteur courbe D D 10 12 16
Courant de démarrage A< CMS
Raccordement hydraulique mm 50 mm
Débit d'eau nominal (a) m3/h 9,1 10,5 12,6
Perte de charge sur l'eau max kPa 17 15 46
Compresseur / Panasonic Panasonic Mitsubishi
Type / Double Rotatif
Quantité / 1
Résistance d'enroulement à 20°C Ohm 0,88 0,88 0,49
Ventilateur / Axial
Quantité 1
Diamètre mm 560 560 600
Nombre de pale / 3
Moteur / DC Inverter
Quantité / 1
Vitesse de rotation Tr/min 500 -- 700 600 -- 750 500 -- 700
Vitesse Mode Silence Tr/min 500 400 400
Niveau de pression acoustique à 1 m dB(A) 56,4 -- 61 55,2 -- 59,7 55,6 -- 59,3
Niveau de pression acoustique à 10 m dB(A) 40,9 -- 45,4 40,9 -- 44,2 36,1 -- 42,2
Dimensions nettes de l'unité (L-l-H) mm 797 x 777 x 965 846 x 920 x 1024
Poids kg 101 101 123
2. CARACTÉRISTIQUES TECHNIQUES (suite)
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward SumHeat Fi Heat Pump - R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward SumHeat Fi Heat Pump - R32 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 28.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info