801893
42
Zoom out
Zoom in
Previous page
1/376
Next page
4
2. TECHNICAL SPECIFICATIONS
2.1 Technical data for the swimming pool heat pump unit
Model HeatRelax HPR06M HPR09M HPR12M HPR19M
Heat capacity (*) kW 4,10 6,30 8,30 12,95
Electrical power rating (*) kW 1,0 1,47 1,91 3,06
COP (*) _ 4,13 4,31 4,33 4,31
Operating current (*) A 4,6 6,61 8,65 13,06
Electrical connection V
Ph/Hz 230 V
1 / 50Hz 230 V
1 / 50Hz 230 V
1 / 50Hz 230 V
1 / 50Hz
Fuse rating aM A8 aM 10 aM 16 aM 20 aM
D-curve circuit breaker A8 D 10 D 16 D 20 D
Heat capacity (**) kW 5,7 9,2 12,1 18,9
COP (**) _ 5,1 5,9 5,6 5,7
Number of compressors _ 1 1 1 1
Type of compressor _ Rotating Rotating Rotating Rotating
Number of fans _ 1 1 1 1
Fan power W 90 120 120 150
Fan rotation speed RPM 850 850 850 850
Fan direction _ Horizontal Horizontal Horizontal Horizontal
Acoustic power (***) Lw dB(A) 66,9 68,8 69,1 68,8
Sound pressure level
(at 10 m) dB(A) 35,8 37,6 37,9 37,5
Hydraulic connection mm 50 50 50 50
Water flow rate (*) m3/h 1,8 2,8 3,6 5,3
Water pressure drop (max) kPa 0,3 2,0 1,8 4,0
Unit net dimensions (L/W/H) mm 746/570/305 956/602/375 956/602/375 1116/871/470
Unit net weight kg 37 51 54 83
(*) Value at +/- 5% in the following conditions: Outside temperature = 15°C / HR = 71%. Water inlet temperature 26°C.
Water outlet temperature 28°C.
(**) Value at +/-5% under the following conditions: Outside temperature 27°C / RH = 78%. Water inlet temperature 26°C.
(***) Measurements according to EN 12102: 2013 and EN ISO 3744: 2010.
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward Heat Relax at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward Heat Relax in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 48.53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info