2. CARACTÉRISTIQUES TECHNIQUES
2.1 Données techniques de la pompe à chaleur
Modèle HeatRelax HPR06M HPR09M HPR12M HPR19M
Capacité calorifique (*) kW 4,10 6,30 8,30 12,95
Puissance électrique (*) kW 1,0 1,47 1,91 3,06
COP (*) _ 4,13 4,31 4,33 4,31
Courant de fonctionnement (*) A 4,6 6,61 8,65 13,06
Alimentation électrique V
Ph/Hz 230 V
1 / 50Hz 230 V
1 / 50Hz 230 V
1 / 50Hz 230 V
1 / 50Hz
Calibre fusible type aM A8 aM 10 aM 16 aM 20 aM
Disjoncteur courbe D A8 D 10 D 16 D 20 D
Capacité calorifique (**) kW 5,7 9,2 12,1 18,9
COP (**) _ 5,1 5,9 5,6 5,7
Nombre de compresseurs _ 1 1 1 1
Type de compresseur _ Rotatif Rotatif Rotatif Rotatif
Nombre de ventilateurs _ 1 1 1 1
Puissance du ventilateur W 90 120 120 150
Vitesse de rotation du
ventilateur RPM 850 850 850 850
Direction du ventilateur _ Horizontale Horizontale Horizontale Horizontale
Puissance acoustique (***) Lw dB(A) 66,9 68,8 69,1 68,8
Niveau de pression sonore
(à 10 m) dB(A) 35,8 37,6 37,9 37,5
Raccordement hydraulique mm 50 50 50 50
Débit d’eau (*) m3/h 1,8 2,8 3,6 5,3
Perte de charge sur l’eau
(max) kPa 0,3 2,0 1,8 4,0
Dimensions nettes de l’unité
(L/l/h) mm 746/570/305 956/602/375 956/602/375 1116/871/470
Poids net de l’unité kg 37 51 54 83
(*) Valeur à +/- 5% aux conditions suivantes : Température extérieure = 15°C / HR = 71%. Température d’entrée d’eau 26°C.
Température de sortie d’eau 28°C.
(**) Valeur à +/-5% aux conditions suivantes : Température extérieure 27°C / HR = 78%. Température d’entrée d’eau 26°C.
(***) Mesures réalisées selon les normes EN 12102 : 2013 et EN ISO 3744 : 2010.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward Heat Relax at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward Heat Relax in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 48.53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info