801902
58
Zoom out
Zoom in
Previous page
1/69
Next page
UTILIZZARE ESCLUSIVAMENTE PARTI DI RICAMBIO ORIGINALI HAYWARD
Pagina 5 di 13 EZ-CHEM Rev. B
Composizione
EZ-Chem
M
pH 7 pH 4
I
N
O G
H
E
FB
C
A
LD
AScatola EZ-Chem
BTubo d’aspirazione flessibile in PVC trasparente
(4 m Ø4x6).
CTubo per l’iniezione in PE bianco semi-rigido
(5 m Ø4x6).
DKit di montaggio
(verificare che vi siano tutte le viti).
EValvola di iniezione (3/8" GAS)
FSonda pH
G Porta-sonda
H(3) x collari di presa in carico per l’iniezione
dell’acido, il sensore di portata e la sonda pH
ISoluzioni tampone pH 7 e pH 4
L Riduzioni per la valvola di iniezione
MSensore di portata
NZavorra per tubo d’aspirazione
OPlacca di fissaggio
Kit ORP per EZ-Chem (optional)
ORP
465
468
I
K
H
B
C
A
D
G
E
F
L
N
www.hayward.fr
Dispense
AScatola della pompa peristaltica
BTubo d’aspirazione flessibile in PVC trasparente
(4 m Ø4x6).
CTubo per l’iniezione in PE bianco semi-rigido
(5 m Ø4x6).
DKit di montaggio
(verificare che vi siano tutte le viti).
EValvola di iniezione (3/8" GAS)
FSonda ORP (redoX)
G Porta-sonda
H(2) x collari di presa in carico per l’iniezione
dell’acido e la sonda ORP
ISoluzione di calibrazione ORP 465 / 468
KPlacca di fissaggio
L Riduzioni per la valvola di iniezione
NZavorra per tubo d’aspirazione
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward EZ-Chem at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward EZ-Chem in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 59.76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info