2. SPECIFICHE TECNICHE
2.1 Prestazioni dell’Unità di Riscaldamento a Pompa di
Calore per Piscine
Modelli ENERGYLINE PRO
INVERTER ENPI4MA ENPI6MA
Tensione di alimentazione V220V-240V / 1ph / 50Hz
Refrigerante / R32
Carica kg 0,50 0,60
Massa in tCO2e / 0,34 0,41
Frequenza di controllo delle perdite /Non obbligatoria, ma consigliata una volta all’anno
Capacità di riscaldamento Min--Max (a) kW 2,50--9,73 5,60--11,9
Potenza elettrica assorbita Min--Max (a)
kW 0,20--1,34 0,52--1,66
Corrente nominale di esercizio Min--Max (a) A 1,33--6,02 2,33--7,29
COP Max--Min (a) / 12,32--7,12 10,77--7,10
Capacità di riscaldamento Min--Max (b) kW 1,71--7,60 4,40--9,20
Potenza elettrica assorbita Min--Max (b)
kW 0,27--1,49 0,69--1,70
COP Max--Min (b) / 6,40--5,1 6,40--5,40
Corrente nominale ammissibile (CMS) A 9,33 12,08
Calibro del fusibile aM 10 16
Interruttore curva D D 10 16
Corrente di avviamento A< CMS < CMS
Allacciamento idraulico mm 50mm
Portata idrica nominale (a) m3/h 4,20 5,20
Perdita di carica sull’acqua max kPa 3,3 3,9
Compressore / DC Inverter Mitsubishi DC Inverter Mitsubishi
Tipo / Doppio rotante Doppio rotante
Quantità / 1
Resistenza di avvolgimento a 20°C Ohm 1,91 0,95
Ventilatore / Assiale
Quantità 1
Diametro mm 405 510
Numero di pale / 3
Motore / DC Inverter
Quantità / 1 1
Velocità di rotazione giri/min. 500--700 500-650
Velocità modalità silenziosa giri/min. 300 400
Livello di pressione acustica a 1 metro dB(A) 33--41 33-41
Livello di pressione acustica a 10 metri dB(A) 16--25 16--25
Dimensioni nette dell’unità (L-l-H) mm 1046/400/768
Peso kg 53 65
(a) Aria asciutta 27°C – Umidità relativa 78% - Temperatura d’ingresso dell’acqua 26°C.
(b) Aria asciutta 15°C - Umidità relativa 71% - Temperatura d’ingresso dell’acqua 26°C.
225


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward EnergyLine Pro Fi Heat Pump - R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward EnergyLine Pro Fi Heat Pump - R32 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 15.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info