2. CARACTERÍSTICAS TÉCNICAS
2.1 Dados técnicos da bomba de aquecimento
Modelos ENERGYLINE PRO
INVERTER ENPI4MA ENPI6MA
Tensão de alimentação V220V-240V / 1ph / 50Hz
Refrigerante / R32
Carga kg 0,50 0,60
Massa em tCO2eq / 0,34 0,41
Frequência de controlo de fuga /Nenhuma exigência mas é recomendado que esta seja
anual
Capacidade de aquecimento Mín--Máx (a) kW 2,50--9,73 5,60--11,9
Potência elétrica absorvida Mín--Máx (a)
kW 0,20--1,34 0,52--1,66
Corrente nominal de serviço Mín--Máx (a) A 1,33--6,02 2,33--7,29
COP (coeficiente de desempenho) Máx--Mín (a)
/ 12,32--7,12 10,77--7,10
Capacidade de aquecimento Mín--Máx (b) kW 1,71--7,60 4,40--9,20
Potência elétrica absorvida Mín--Máx (b)
kW 0,27--1,49 0,69--1,70
COP (coeficiente de desempenho) Máx--
Mín (b) / 6,40--5,1 6,40--5,40
Corrente máxima de serviço (CMS) A 9,33 12,08
Calibre do fusível aM 10 16
Disjuntor curva D D 10 16
Corrente de arranque A< CMS < CMS
Ligação hidráulica mm 50mm
Caudal de água nominal (a) m3/h 4,20 5,20
Perda de carga na água máx kPa 3,3 3,9
Compressor / DC Inverter Mitsubishi DC Inverter Mitsubishi
Tipo / Duplo Rotativo Duplo Rotativo
Quantidade / 1
Resistência de enrolamento a 20°C Ohm 1,91 0,95
Ventilador / Axial
Quantidade 1
Diâmetro mm 405 510
Número de pás / 3
Motor / DC Inverter
Quantidade / 1 1
Velocidade de rotação Rpm 500--700 500-650
Velocidade Modo Silêncio Rpm 300 400
Nível de pressão acústica a 1 m dB(A) 33--41 33-41
Nível de pressão acústica a 10m dB(A) 16--25 16--25
Dimensões (sem embalagem) da unidade
(C-L-A) mm 1046/400/768
Peso kg 53 65
(a) Ar seco 27°C - Humidade relativa 78% - Temperatura de entrada da água 26°C.
(b) Ar seco 15°C - Humidade relativa 71% - Temperatura de entrada da água 26°C
117


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward EnergyLine Pro Fi Heat Pump - R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward EnergyLine Pro Fi Heat Pump - R32 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 15.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info