801895
8
Zoom out
Zoom in
Previous page
1/400
Next page
4
2. CARACTÉRISTIQUES TECHNIQUES
2.1 Données techniques de la pompe à chaleur
Modèles ENERGYLINE PRO
INVERTER ENPI7M ENPI9M ENPI11M ENPI13T
Capacité de chauffage nominale(a) kW 7,05 9,20 11,40 13,40
Puissance électrique absorbée(a) kW 1,33 1,81 2,18 2,60
COP(a) / 5,30 5,08 5,23 5,15
Tension d'alimentation V230V230V230V400V
Phase / 1N1N1N3N
Fréquence Hz 50 Hz 50 Hz 50 Hz 50 Hz
Courant nominal de service(a) A 5,69 7,8 9,32 4,47
Courant maximum de service (CMS) A 15,5 21 25,9 11,4
Calibre du fusible aM 16 25 32 16
Disjoncteur courbe D D 16 25 32 16
Courant de démarrage A< CMS < CMS < CMS < CMS
Raccordement hydraulique mm 50
Débit d'eau nominal(a) m3/h 3,20 4,00 4,70 5,70
Perte de charge sur l'eau max kPa 4,60 7,00 11,60 5,10
Compresseur / Rotatif
Type / Inverter
Quantité / 1
Réfrigerant / R410A
Charge kg 1,10 1,30 1,80 2,10
teqCO2/ 2,30 2,71 3,76 4,38
Fréquence du contrôle de fuite /Pas obligatoire mais conseillé
Ventilateur / Axial
Diamètre mm 500
Quantité / 1 1 2 2
Moteur / Inverter
Quantité / 1 1 2 2
Vitesse de rotation Tr/min 500...750 500…900 400…800 400…850
Niveau de pression acoustique à 1m dB(A) 44-53 45-56 46-57 48-58
Niveau de pression acoustique à 10m dB(A) 27-36 28-39 29-40 31-41
Dimensions nettes de l'unité (L-l-H) mm 1117 / 485 / 868 1115 / 485 / 1275
Poids kg 77 82 110 113
(a) Les capacités de chauffage nominales sont basées sur la Norme d’essai NF EN 14511
reprise dans le référentiel NF-414.
Air se c 15°C - Humidité relative 71% - Température d’entrée d’eau 26°C.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward EnergyLine Pro - R410 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward EnergyLine Pro - R410 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 51.25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info