801896
71
Zoom out
Zoom in
Previous page
1/328
Next page
31
6. APPENDIX (continued)
Problem Error
codes Description Solution
Water inlet sensor fault P01
The sensor is open or has short-circuited.
Verify the CN21/RES1 connectors on
the board and the extension connector
or replace the sensor
Water outlet sensor fault P02 Verify the N22/RES2 connectors on the
board and the extension connector or
replace the sensor
Outside temperature sensor fault P04 Verify the CN12/PH connectors on the
board and the extension connector or
replace the sensor
De-icing sensor fault P05 Verify the CN8/OPT connectors on the
board and the extension connector or
replace the sensor
Compressor aspiration sensor defect P07 Verify the CN7/OAT connectors on the
board and the extension connector or
replace the sensor
Compressor discharge sensor fault P081 Verify the CN9/OHT connectors on the
board and the extension connector or
replace the sensor
High pressure protection E01 The sensor is open or has short-circuited.
Verify the CN30/HP connectors on the
card or replace the sensor
Check the water flow
Check the water flow detector
Check the valve opening
Check the by-pass
Check the evaporator is not clogged
Water temperature too hot
Incondensable problem after
maintenance, empty and evacuate the
cooling circuit
Fluid load too high, remove fluid into a
liquid bottle
Low pressure protection E02 The sensor is open or has short-circuited.
Check the AI/DI03 connections on the
card or replace the sensor
Large coolant leak, search for the leak
with the detector
Air flow too low, check the ventilator
rotation speed
Check the evaporator is not clogged,
clean its surface
Flow sensor fault E03 The sensor is open or has short-circuited.
Check the AI/DI02 connections on the
card or replace the sensor
Lack of water, check the filtration pump
operation
Check the stop valve opening
Check the by-pass adjustment
71


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward EnergyLine Pro - R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward EnergyLine Pro - R32 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 15.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info