801904
16
Zoom out
Zoom in
Previous page
1/68
Next page
16
13. VARIABLE SPEED PUMP
Once the WIFI module is connected to the network with both lights ON, enter in https://poolwatch.
hayward.fr/login. Access the Register option and enter all the data requested. The unit ID node can
be found on your device (see section 8. System Settings - screens 8.13 & 8.14). Upon completion of
the process, you will have total control of your pool, will be able change parameters such as setpoints,
filtration hours and turn ON/OFF any auxiliary relays.
13.1 Variable Speed Pump: To install a
Variable Speed Pump contact your installer.
13.2 a 13.6 After connecting the pump, you
can individually assign each filtration period
a different speed
F: fast, M: medium and S: slow.
8.17 8.18
8.19 8.20
8.15 8.16
8.21 8.22
13.1 13.2 13.3
8.1 WIFI SETTINGS
8.15 Internet: Once the WIFI module is connected, restart
your unit. In the Settings menu will appear the Internet option.
8.16 WIFI: Select WIFI to scan the available networks
accessible to the module. The search will be done
automatically.
8.17 Select the desired network accessible to the WIFI module.
8.18 Enter the password in the pop-up keyboard. Scroll up and
down with the up/down keys and left to right with the plus/
minus keys. To select a letter press the OK.
8.19 Configuration: For a more detailed configuration enter
this menu or contact your installer.
8.21 Status: Check the status of your connection.
8.22 Test connection: Check that your connection has been
successfully established.
Connection
WIFI module
Green LED
(ON)
1 red 2 yellow
3 green 4 black
13.7 Filter cleaning:
To clean the filter
with a Variable
Speed Pump, you
should use the
fastest speed.
13.713.4 13.5
9.1 9.39.2
9.4 9.5
9. SALINITY* 10. COVER
10.1 Cover: Connection of automatic cover.
10.2 Reduction of chlorine production in percent, when the pool cover is closed.
With the cover closed is not necessary for the system to run at 100%. With this
parameter, regulates the optimum amount of chlorine generation.
10.1 10.2
Cover 1 & 5
1
2
3
4
5
6
7
8
11. FLOW SWITCH
It is possible to add an external
flow switch to the system.
Connect as shown in the image
and contact your installer for
activation. The titanium cell
includes a gas flow sensor, you
can combine both for better
control.
Optional Flow switch 1
2
3
4
5
6
7
8
Flow switch FL1 2 & 5
Mechanic security
flow switch. Stops the
hydrolysis/electrolysis and
the dosing pumps if there is
no water flow.
9.2 To acknowledge this measure, press OK in Salinity in the Electrolysis/Hydrolysis
menu (the process takes between 2 and 5 minutes - display 9.4). You can adjust the
system measure using a external salt measurer (display 9.5).
9.3 If you do not have a temperature probe, enter the value manually for greater
accuracy. The lecture is influenced by many factors, like the water temperature or
the pH. Remenber to do the adjustment every 2-3 months.
* Be careful: Option only available for some models.
9.1 Salinity: The device
shows a measurement
of salt in water in g/l,
as well as the date and
water temperature of
the last reading.
110-230 V max. 3.15 A DRY CONTACT
12 3 45 6 78 9 10 11 12 13 14
FILTER PUMP
Filtration control
7 & 8
Variable Speed Pump
1 slow 2 medium 3 fast 4 common
14
12 11
A1 A2
LN
12. LEVEL SENSOR (Tank)
Connect a level sensor to your device so you can control at all times the volume available in the tanks of chemicals that your system
commonly uses. Contact your installer/provider to activate the sensor. This way you can ensure that the dosing pumps never run out
of product and doses in vacuo, avoiding possible damages.
3
4
5
6
Acid deposit
level TANK 4 & 5
13.6
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward AquaRite UV LS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward AquaRite UV LS in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 6.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info