801906
147
Zoom out
Zoom in
Previous page
1/166
Next page
UTILIZZARE SOLO PARTI DI RICAMBIO ORIGINALI HAYWARD
Pagina 8 di 23 AquaRite + Rev. E
Installazione e collegamento elettrico
Collegare AquaRite + a una presa di alimentazione elettrica fissa.
: Il circuito deve essere protetto da un interruttore differenziale (DDR) (corrente residua : 30mA max).
110-230 V
max. 3.15 A
Cover
FL1
pHredoX
pH
12 3 4 5 6 7 9 10 13 1411 12
8
A
B
C
D
E
F
G
AUX 1
1
2
3
4
A1
A2
N L
LIGHT
1
2
3
4
A1
A2
L
N
AUX 4
EnergyLine / Easy Temp / EcoPac / PowerLine
H
Level
AUX 2
1
2
3
4
A1
A2
N L
AUX 3
1
2
3
4
A1
A2
L
N
FILTER PUMP
1
2
3
4
A1
A2
L
N
FS HP
LP
TC
12V Controller
BLU
Y/G
BRN
FS
FS
LP
LP
HP
HP
2 2
t
5K
t
5K
t
5K
t
5K
IT
IT
OT
OT
AT
AT
CT
CT
OUT3
OUT4
OUT5
AC-N
3
4
3
4
CN19
GND
AI05
GND
AI04
GND
AI03
GND
AI02
GND
CN1
CN2
12V
NET
GND
DI01
GND
DI02
GND
DI03
GND
DI04
GND
DI05
GND
AI01
GND
DI06
GND
CN6
AI06
CN16
GND
+5V
t
5K
SUT
SUT
OUT1 OUT2
Descrizione dei relé di uscita
Nome Descrizione Morsetti Tipo di uscita Imax
pH Pompa peristaltica acido 230 V1 - 2 Uscita Tensione 1 A
Aux1 Uscita Tensione Ausiliaria 230 V3 - 4 Uscita Tensione 1 A
Aux2 Uscita Tensione Ausiliaria 230 V5 - 6 Uscita Tensione 1 A
Filter Pump Controllo Pompa di filtrazione 7 - 8 Contatto secco
Light Controllo Illuminazione 9 - 10 Contatto secco
Aux3 Contatto secco Ausiliario 11 - 12 Contatto secco
Aux4 Contatto secco Ausiliario (o Controllo riscaldamento) 13 - 14 Contatto secco
Se nessun sistema di riscaldamento è installato sull’Aux4, questo può essere utilizzato come altro contatto ausiliario. Per
far ciò, contattare l’assistenza tecnica Hayward.
Opzione display a distanza
Opzione modulo WiFi
pompa a
velocità variabile
Sonda
temperatura
Sonda
temperatura
redoX pH
A
B
C
D
E
F
G
H1 2 3 4 5 6 7 8 9 10 11 12 13 14
i J K
147


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward AquaRite Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward AquaRite Plus in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 66.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info