Press the SCAN button to start measurement. At the beginning of
measurement a brief tone sounds.
Move the thermometer along the forehead towards the temple. During the
duration of the measurement, the LED lamp over the SCAN button is lit. At
the end of measurement, a long tone is sounded and the measuring result
is displayed. The forehead measurement takes three seconds.
The thermometer symbol will appear three seconds after the measurement, and the device is
ready for the next measurement.
Important information for forehead measurement:
We recommend measuring the temperature at the same position every time as otherwise the
displayed values may vary.
Remove hair, perspiration, cosmetics or dirt from the forehead to ensure an optimum
measurement accuracy.
Please observe that the forehead temperature may be influenced by staying outside for a longer
period of time (in the cold in winter or in strong solar radiation in summer, for example) as well as
by wearing a headgear.
It is recommended that the forehead measurement is carried out after at least 30 minutes in room
temperature.
In order to ensure that the Arteria temporalis (temporal artery) is included during the measuring
process, it is necessary to carry out the scan movement right up to the temple area, including the
temple.
Switching over from ear to forehead measurement (or vice versa) is effected automatically by means
of a contact sensor in the thermometer tip. The thermometer recognizes automatically which mode is
operational.
English
GB
3 sec.
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hartmann Thermoval Duo Scan at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hartmann Thermoval Duo Scan in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 2,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hartmann Thermoval Duo Scan

Hartmann Thermoval Duo Scan Specifications - Dutch - 2 pages

Hartmann Thermoval Duo Scan User Manual - Portuguese, Spanish - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info