Phenomenon Cause or check points
Poor cooling or poor
heating
Is the air filter dirty?normally it should be cleaned every 15 days.
Are there any ostacles before inlet and outlet?
Is temperature set correctly ?
Are there some doors or windows left open?
Is there any direct sunlight through the window during the cooling
operation(use curtain)
Are there too much heat sources or too many people in the room
during cooling operation?
IS the horizontal flap direction right?
It should be kept horizontal or upward during cooling operation
while set horizontal or downward during heating operation.
Water leakageThe air filter is dirty .The unit is tilt installed.
A swishing or gurgling noise
is heard
During unit operation or at stop, a swishing or gurgling noise may be
heard .At first 2-3 minutes after unit start, this noise is more noticeable
(This noise is generated by refrigerant flowing in the system.)
A cracking noise is heard During unit operation, a cracking noise may be heard.This noise is
generated by the casing expanding or shrinking because of
temperature changes.
Smells are generated The is because the system circulates smells from the interior air
such as the smell of furniture, paint, cigarettes.
Mist or steam are blown outDuring COOL or DRY operation, indoor unit may blow out mist.
This is due to the sudden cooling of indoor air.
COOL mode changes to FAN
mode automatically
To avoid frosting on the heat exchanger of the indoor unit, the air
conditioner sometimes changes to FAN mode in COOL operation.but
immediately it will change back to COOL mode.
The system does not restart
immediately
In HEAT mode, the outdoor
unit generates water or steam. This is because the frost on the heat exchanger of the outdoor unit
is melting (in COOL operation) .
the fan motor of indoor unit will
continue running even though
the HEAT operation is stopped.
For the sake of removing the remaining heat, the fan motor of
indoor unit will continue running for some time after the heat
operation’s stop.
In DRY mode, fan speed can’t
be changed.
In DRY mode, when room temperature becomes lower than temp.
setting +2 unit will run intermittently at LOW speed regardless
of FAN setting.
None of the units operates
Check the power supply: make sure the rated voltage is supplied.
Check if the residual current circuit breaker trip?(make sure cut off
the power supply off and contact the service station immediately. )
The temperature displayed on
the control panel is different
from the temperature detected
by the user
In consideration of the temperature difference in the room,
the air conditoner will automatically compensate the temperature
In order to improve the comfortableness .therefore it is normal
phenomenon.
When unit is stopped, it won’t restart immediately unit 3 minutes have
elapsed to protect the system. When the electric plug is pulled out
and reinserted, the protection circuit will work for 3 minutes to protect
the air conditioner.
Trouble shooting
20
c
o
h
s
i
l
g
n
E
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haier Zun Tower at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haier Zun Tower in the language / languages: English as an attachment in your email.

The manual is 16.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info