1. Insert from outside the room cable into left side of the wall
hole, in which the pipe has already existed.
2. Pulloutthe cableonthe front side, and connect the cable
making a loop.
outdoorunits carefully. If wiring is not correct, properoperation can not
Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then
tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and
tightened.
After the cable connection, never fail to fasten the connected cable with the
wiring cover.
When connectingthe cable afterinstallingtheindoor unit
When connectingthe cable before installing the indoor unit
Note:
1. If the supply cord is damaged, it must be replaced by the manufacturer or its
H05RN-F or H07RN-F.
2. If the fuse on PC board is broken please change it with the type of
3. The wiring methodshould be in line with thelocal wiring standard.
4. Afterinstallation, thepower plugshould be easilyreached.
all-pole switch andthedistance between its two contacts shouldbenotless
than 3mm.
T.3.15A/250VAC (Indoor).
To Outdoor unit
Connecting wiring
4G1.0mm
2
C od e
indication Trouble description A nalyze and diagnose
E1
E2
E4
E7
E14
H ea t-exc hange
sensor failure
Indoor EEPR O M
error
C om m unication
fault betw een
indoor and outdoor
units
Indoor fan m otor
m alfunctio n
Operation halt due to breaking
of wire inside the fan m otor;
Operatio n halt d ue to break in g
of the fan m otor lead w ires;
D ete ction e rro r due to faulty
indoorunit P C B ;
Indoorunit- outdoor unit signal
transm issio n e rro r du e to w iring
error;
Faulty P C B ;
F au lty E E PR O M da ta;
Faulty EEPR O M ;
F au lty P C B ;
Faulty connector connection;
Fa ulty therm istor;
Faulty P C B ;
Room temperature
sensor failure
The power source must be exclusivelyused for airconditioner.
In the case of installing an air conditionerin a moistplace, pleaseinstall
an ea
For installation in other places, use a circuitbreaker as faras possible.
Pipe cutting is carriedout with a pipe cutter andburs must be removed.
Power Source Installation
CuttingandFlaring Work of Piping
Clutch-type clutch-type(Rigid-type) Wing-nut type (Imperial-type)
A 0~0.5mm 1.0~1.5mm 1.5~2.0mm
rth leakagebreaker.
Lean
tcerrocnItcerroC
On Drainage
It becomes
high midway. The gap withthe
ground is too small.
Thereisthebad
smell from a ditch
It waves.
Theend is imm-
ersed in water.
Please install the drain hose so as to be downward slope without fail.
Pleasedon’t do the drainage as shown below.
Please pour water in the drain pan of the indoor unit, and
is carried out surely to outdoor.
In case that the attached drain hose is in a room, please applyheat
insulation to
Lessthan
5cm
drainage
it withoutfail.
Crack
Indoor unit
Check Itemsfor Test Run
Gas leak from pipe connecting?
Heat insulation of pipe connecting?
Is drainage securely carried out?
Is theearth linesecurely connected?
Is power source voltageabidedbythe code?
Is there any noise?
Is the lampnormallylighting?
Are cooling and heating (when in heat pump) performed normally?
Is the operation of room temperature regulator normal?
Please kindly explain to our customers how to
operate through the instructionmanual.
inserted to the terminalblock?
Put check mark in boxes
Flare toolingdie1.Cut pipe 2.Remove burs
4.Flare pipe
On Drainage
Check for Installation and Test Run
AS25JBJHRA-W
4G1.5mm
2
AS35JBJHRA-W
AS50JDJHRA-W
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haier Jade serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haier Jade serie in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 55.64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haier Jade serie

Haier Jade serie User Manual - Dutch - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info