659859
4
Zoom out
Zoom in
Previous page
1/8
Next page
4
Safety Instructions
To ensure that the burr/ tool sits firmly
in the chuck, do not work with tools
which:
have an oily shaft
are worn
are bent.
Before using the equipment, assure
that:
the tool can be pushed far enough
into the chuck
(Test this with a dipstick and clean
if necessary)
the inserted tool will not cant
while clamping it
the tool stuck properly in the chuck
the tool is approved for using it at
the max. speed (see manufactur-
er’s instructions)
the tool is absolutely dry.
For safety reasons do not change the
tool while the motor is running.
Empty the unit if it is not in use for a
longer period of time (e.g. before vaca-
tions). Clean out the tank. Set the
spray function on maximum. Now start
the spray function, and the water will
spray for approx. 3 min. The fluid will be
blown out of the complete spray system
and handpiece.
Always follow the operating instructions.
Do not carry out any repairs, modifica-
tions or maintenance work yourself.
This should only be done by a special-
ist. The mains cable may only be
changed by the producer. Never re-
move the housing, while the equipment
is plugged in as some components are
live. A spare parts list may be supplied
to qualified persons (repair workshops).
No responsibility can be accepted for
unauthorized or improper tampering
with the unit, which nullifies the guaran-
tee and any other liabilities.
Cleaning and disinfection
After every treatment please carry out
this steps:
Remove the rotating tool (e.g. bur) first.
To do so, pay attention to the instruc-
tions of its manufacturer.
Remove clothing remains through wip-
ing off easily the unit with a moistened
paper cloth. Afterwards clean all surfac-
es with a disinfection cloth (e.g.
Mikrozid AF cloths of Schülke and
Mayr).
13
Technical Details
Handpiece vibrates, is loud and/ or
becomes hot at the front part
Using bent tools if so use a different
tool. (You can proof your tool with
our testing device 4990 if it is crook
or bent.)
Max. speed of the drill has been ex-
ceeded, which could cause a higher
vibration. if so, consider instruc-
tions of the manufacturer of the bur.
Bur can not be insert easily
Use of bent / crook burs if so uses a
different tool. (You can proof your
tool with our testing device 4990 if it
is crook or bent.)
Chuck is full of dirt cleaning the
chuck (see page 11)
Bur can not be clamped (does not
run)
Chuck is not tightened well
Tighten the chuck according to in-
structions on page 7.
Knob of the handpiece is hard to use
Chuck is dirty/ soiled clean the chuck
according to page 7.
Rubber ring under the knob twists while
using it. Twist it of 180°
It does not spray
Pressure can not be set up in the tank,
because the lid is not tightened well.
There are parts of dirt in the spray sys-
tem cleaning the spray system
according to page 10.
The blue water filter (art. No. 3479) in
the tank is blocked Change the
water filter.
The unit does not work at all
Check the position of the main switch at
the back of the unit. It should be set on
“I“. (ON)
Foot switch is used all the time or it is
broken Take off the socket of the
switch and try to start the machine
without the switch.
Pull the main switch to re- set the con-
trol unit.
After longer in use, it does not spray
Unit is overheated. Slots of the unit
should not be covered or blocked.
Let cool down the unit for a while.
The noise level of the unit various
with its location
Depending on the background, where
the unit had been set up, the noise
level will vary.
The motor of the handpiece stutters
(e.g. 1 sec.) while switching it on
Very seldom this error might occur.
It would not damage the motor at all.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hadewe Hyperios3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hadewe Hyperios3 in the language / languages: English as an attachment in your email.

The manual is 1,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hadewe Hyperios3

Hadewe Hyperios3 User Manual - German - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info