between them). If the glass is dirty, we recommend increasing the firing intensity by
opening the primary air regulator, which usually supports the self-acting cleaning process.
5.5. Operation during temporary period and at worsened weather conditions
For temporary periods , for example, during the time when outdoor temperature is above
15
o
C, during rainy and wet days, in case of gusty wind, etc. the chimney effect may worsen
thus the smoke is not led away in full as usual. Therefore, during such period, you should
operate the fireplace stove with smallest possible quantity of fuel, to allow improving the
firing process and the chimney effect by opening the air inlets in case you need to make
adjustments.
5.6. How to substitute the blind element by the exchanger
Some models are provided with the so-called blind element that serves as the chimney
effect conditioner as well. After removal of such blind element, those models must be
completed with warm-water exchanger allowing connection to heating bodies to provide
heat in adjacent rooms or with a water back boiler. A warm water exchanger may be
supplied as special accessory (detailed instructions for operation and installation provided).
Order the installation of the fireplace stove with warm water exchanger at a specialist
company.
Caution! A fireplace stove equipped with a warm water exchanger must not be
operated without the connection to the warm water distribution system or the water
filled, or without anti-freezing mixture, respectively.
5.7. Ash removal
Depending on the length and the intensity of the firing process, you need to use a fire hook
or poking lever (if installed with the particular model) in order to knock the ash down the
grate to the ashpan. Monitor the content of the ashpan - do not allow too much ash in
it. Excessive ash may block the air supply under the grate thus causing problems at
fire setting or burning.
Always empty the ashpan when cold. The best approach is to empty the ashpan just before
you start preparing the next fire. Ash from wood may be used for composting or for
fertilizing.
Caution! Before you touch the ashpan to empty it, check it for fire brand. Prevent any
likely fire in the dustbin.
6. CLEANING AND MAINTENANCE
6.1. Cleaning
The fireplace stove (cold) needs cleaning at least once a year (after the season), or twice
or more (if needed). During the cleaning, you should remove any dirt caught in the smoke
flue, the firing area and on the partitions. Loose parts of the fireclay lining should be
repaired (i.e. replaced). Check the fireclay lining for integrity even during the heating
season. The gaps between the brick shapes are designed for heat dilatation, to avoid brick
cracking. Therefore YOU SHOULD NOT fill any sealing in the gaps (as it used be before
with older heating devices). Cracked fireclay bricks do not lose the function unless
they are completely fallen out of the position!
In the course of the cleaning procedure, we recommend you to remove all movable
partitions (for easier access in the area above them). To clean the glass, apply standard
cleaning agents designed for cleaning fireplace stove, cooker or oven. Use a soft cloth or
paper, or special agents designed for cleaning fireplace glass, e.g. CINEOL. Only clean the
glass when cold. For cleaning the painted surface, never use water: it is recommended to
clean such surface with sponge or soft flannel cloth.
Caution! With selected types of fireplace stove, the vertical side of the firing area is
provided with VERMICULITE. The same material is used for some chimney effect
conditioners. The material is irreparable. In case of any damage, just replace it.
Vermiculate products are characteristic with top heat-insulating parameters and good
resistance to cracking. The resistance to abrasion is somehow lower so it is recommended
to keep this in mind while reloading and cleaning.
6.2. Cleaning the ceramics and tiles
To clean ceramic tiles or tiles, it is recommended to use a dry or slightly wet cloth. Clean
the fireplace stove only while cold.
6.3. Sealing lines and tapes
Contact areas of doors and glass (or other parts of the heating device) are provided with a
special glass-ceramic sealing line (tape) that is resistant to high temperatures. We
recommend you to check the tape for integrity, and have it replaced if necessary.
After some time, any newly installed sealing tape lays flat so it is recommended to check
the tightness (the glass tightly installed in the door construction) after approx. 3 months of
usage. If you find any release, tighten the glass holders (carefully!)
6.4. Spare parts
In case of repair, use only original spare parts recommended by the manufacturer, see
Chapter 10.3 (Recommended spare parts). Identify the spare part with use of the Technical
Card (a part of the supply).
7. WHAT TO DO IF... ...Do you do it yourself?
Problem Cause Corrective action
Chimney or smoke flue sealing
(malfunction, “false” air is being
added).
Contact a chimney sweep (ask them to check the chimney).
For example, new sealing for the chimney door is needed.
Adjust the positions of smoke pipes or replace them if
damaged.
Chimney effect bad or not
working
Ask the chimney or fireplace stove specialist technician for
inspection to find out the reason and the solution (e.g.
cleaning the chimney, remove the smoke flue reduction
elements, higher chimney, more air in the room, etc.
The door of another heating
device connected to the same
chimney is open
Shut the door
Chimney cleaning holes are
open.
Close the cleaning holes
Smoke flue elements or
other parts of the heating
system are dirty or clogged
See 6.1.
Insufficient fresh air supply See 4.7.
Worsened weather conditions See 5.5.
Malfunction (weak fire, weak chimney effect) or excessive
smoke during reloading or during the firing
Wrong type of fuel was used for
burning
Provide proper kind of fuel, see 2.2.
12
13
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn TERME at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn TERME in the language / languages: English as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info