FOR THE HEATING DEVICE AND SMOKE
FLUE (dimensions in mm)
Printed: TISKÁRNA ŘEHÁK Česká Lípa, Czech Republic, Tel.: +420 487 853 897
PASSAGE THROUGH THE FIRE
PROOF SMOKE FLUE WALL
(dimensions in mm)
1 – Wall
2 – Smoke flue system
3 – Cover (fireproof, non-metal)
4 – Rosette
5 – Protective pipe (fireproof, non-metal)
6 – Insulating filler I (fireproof, e.g. glass fibre)
7 – Insulating filler II (fireproof, e.g. filler designed
for stoves)
1 – Ceramic (metal) insert
2 – Metal chimney body
3 – Chimney walling
4 – Metal smoke flue system
5 – Hole in the chimney body
6 – Sealed branch to the chimney body
7 – Shim, fixed to the body with metal tapes
8 – Dilatation gap between the brick shape and the chimney walling
CORRECT – see. c, d WRONG see a, b
Comment
s on ČSN 73 4201 :
2008
CLEARANCE BETWEEN THE INSERT
AND THE SURROUNDINGS
SMOKE FLUE CONNECTION IN THE
CHIMNEY BODY HOLE
Minimum clearances
A>=800 mm
B>=400 mm
1 – Protective barrier for the heating device and smoke flue
protecting surrounding constructions against
heat
2 – Hole for feeding and ashpan
19
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn RHONE II RAINBOW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn RHONE II RAINBOW in the language / languages: English as an attachment in your email.

The manual is 0,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info