7
Next, set the lever to the position "Ignition" again ON, so that the time interval to the inflammation of fuel
might be as short as possible.
As soon as fuel starts burning lively, the lever is to be re-set again to "Heating operation regime".
5.5.2. Chimney stove without EASY CONTROL
Before opening the firebox door, all registers should be closed, in order to minimize the escape of flue gases
into the living space.
After having added fuel (concerning the max. admissible quantity), close the firebox door shut again.
Next, the regulation of primary and secondary air must be opened to maximum.
Once the fuel starts to burn, the primary air regulator must be closed - the secondary air regulator remains
open. Exception for secondary air control: In the case of the Auto Air device function, eventually in the case
of Auto Air coal, the air regulation cannot be adjusted manually, because it works automatically.
5.6. Overheating
WARNING
In order to avoid damage to the appliance due to overheating, there must not be exceeded the maximum
oneshot stoking amount of fuel (see specification of the appliance). It can bring about damage to fire clay,
grate, pile grating, formation of fissures in tiles, tinting of parts of the casing, heat accumulating bricks and
glass, deformation of metal sheet parts, destruction of sealing and of the glass board of the cover etc. All the
rights arising from the guarantee cease to exist.
5.7. Removal of ashes
After longer heating, but once a week at least, it is necessary to rake out ashes into the ash-pan by means of a
poker, and to empty the ash-pan. Please mind to empty the ash-pan meanwhile it is approximately half-full, so
that the layer of ashes may not touch the grate.
CAUTION
There is a danger that the circulation of air might be interrupted, and of insufficient cooling as the
consequence, which can bring about overheating and damage to the grate.
WARNING
Before removal of ashes, check always whether there are no remains of live fuel in the ashes. Even in cold
ashes, there may possibly remain rests of live fuel, and bring about fire in the waste bin.
6. Cleaning and servicing
Once in a year at least, or more often in case of need, you should clean the fireplace stove in cold state, and
service it. During the servicing, it is necessary to remove accumulated ashes from the tube of the smoke
flue and from boards changing the smoke direction or from the return draft boards. The return draft boards
can be taken out for cleaning (see the specification of the appliance).
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn PYRUS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn PYRUS in the language / languages: English as an attachment in your email.

The manual is 2.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn PYRUS

Haas-Sohn PYRUS User Manual - German - 8 pages

Haas-Sohn PYRUS User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info