11. Faults, causes, correction
You can correct simple faults yourself with the following guide. For further information please
consult your specialist dealer.
Attention! All devices are equipped with a large number of safety devices. If a fault occurs, you
will be shown this on the display.
In the event of a fault, leave the mains plug in so that the internal safety functions can
continue to operate fully. Do not pull out the mains plug until you are about to work on the cold
device.
11.1. Error messages on the display
1. OC initiated Check burner (Error number 1)
Cause:
OC triggered because of overheating
Or fuse ( F4 ) in the central unit is
defective
Correction:
Change fuse ( F 4 )
If the OC has been triggered, you must
contact the service engineer
2. Ignition phase target temp. flue gas not
reached (Error 2) Check burner
Cause:
The transition temperature from the
Ignition phase to Heating mode was not
reached.
Correction:
Check pellet stock. (See Instructions 7.2)
Check that the chute between the burner
and the screw conveyor is clear
Contact the service engineer
3. Shutoff materials correction (3) Check burner
Cause:
The automatic fuel reduction has initiated
a safety shutdown
Correction:
Set the heating profile as description
Room temperature sensor is on the floor
or on the wall hang the sensor free
Contact the service engineer
4. Shutoff flue gas temp. Heating mode (5)
Cause:
Flue gas temperature is starting to fall
rapidly despite maximum heat output for
a long period
The following circumstances might lead to this:
No pellets present
The screw conveyor is not rotating, it is
jammed, the screw conveyor motor is
defective or the chute is not clear
The required combustion air cannot be
supplied to the stove e.g. via a vapour
extractor hood that is located in the
vicinity of the installation site and
switched on.
Burner dirty
Suction filter dirty
Room too airtight required combustion
air cannot be replenished in the room
Poor seals on the pellet stove (door,
seals)
Flame temperature sensor wrong
Flue gas temperature wrong
Correction
Check pellet stock
Check that the chute between the pellet
tank and the burner is clear.
Clean the burner and suction filter
Check whether there is a vapour
extractor hood present and in operation
Make sure for instance that a window is
left open a crack to supply the required
combustion air
Contact the service engineer
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn PALLAZZA 532.08 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn PALLAZZA 532.08 in the language / languages: English as an attachment in your email.

The manual is 4.05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn PALLAZZA 532.08

Haas-Sohn PALLAZZA 532.08 User Manual - German - 36 pages

Haas-Sohn PALLAZZA 532.08 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info