4.1. Weather conditions
For the safe operation of the fireplace, it must be ensured that the chimney is able to build up the necessary
flue draft. Particular attention needs to be paid to this during the transition period (E.G. autumn and spring) or
during poor weather conditions (E.G. strong wind, fog etc.).
4.2. Chimney flue draft at rated heat output of the stove
min. flue draft: 6 Pa
- if the minimum flue draft is not reached, then it is not possible to operate the
fireplace properly and it will lead to increased contamination of the burner
and inspection window.
max. flue draft: 15 Pa - if the maximum permitted flue draft is exceeded, this leads to increased fuel
consumption.
4.3. Connection to the chimney
CAUTION
For the connection to the chimney, gas-tight flue tubes should be used. Approved flex steel tubes are also
suitable. Please observe the national regulations.
The flue tube must be securely fitted on the flue gas spigot.
The flue gas tube must not be installed with a drop to the chimney.
It is also essential to ensure that the flue tube does not stick out into the open cross-section of the chimney,
which would interfere with the flue gases rising and prevent the optimal cleaning of the chimney.
The use of wall lagging is recommended for the insertion into the chimney.
Longer horizontal flue gas connections reduce the necessary flue draft.
All openings leading into the same chimney, such as stove and chimney cleaning apertures, must be
closed.
4.3.1. Multiple use
The stove is not approved for multiple use.
4.3.2. Connection to the existing chimney (example)
The plug for outlet of the condensate is of help in the cleaning and in the generation of the condensate.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn HSP 8 Volterra at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn HSP 8 Volterra in the language / languages: English as an attachment in your email.

The manual is 1.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn HSP 8 Volterra

Haas-Sohn HSP 8 Volterra User Manual - German - 32 pages

Haas-Sohn HSP 8 Volterra User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info