811874
20
Zoom out
Zoom in
Previous page
1/32
Next page
GB
16
9.1.6. Service
main menu The service interval can only be reset after burning more than 1 kg
of pellets.
After that, the service interval can be restored.
Service in 998 kg
Reset the service interval?
OK
main menu Vorgangsweise:
By pressing the "OK" button, you will be asked whether you really
want to reset the service interval.
By pressing the "Yes" button, the service interval will be reset to
1000 kg and an error code W0042 will be logged into thee Error
Log.
To exit the function, press the "No" button.
Are you sure, you want to reset the
service interval?
No Yes
9.1.7. Power Stage Blower (optional only on HSP 7–RLU)
Power Stage Blower Procedure:
The desired fan speed can be selected with the "Plus" or "Minus"
buttons.
The higher the selected value, the higher the speed of the blower.
Pressing the "OK" button saves the setting.
To exit the function, press the "On/Off" button.
Power Stage Blower
Setpoint Blower
(1) 1[ ]
OK
9.1.8. Manual filling (optional only on HSP 8)
main menu Procedure:
The required line can be selected with the "Plus" or "Minus"
buttons.
Press "OK" button on the right to switch on.
The screw conveyor then turns, thus feeding the pellets.
As soon as the pellets move into the burner via the chute, the feed
process is stopped by pressing the "OK" button.
manual filling
pulling-in motor Off
On
Note
Filling manually is used for the first use and when the pellet tank has emptied.
9.1.9. Record of defects
Record of defects Procedure:
By means of the push-buttons "Plus" or "Minus", it is possible to
review the existing faults with dates and times.
In the record of faults (memory of faults), there are shown the latest
64 error messages with dates and times.
In order to leave this function, Press the button "On/Off".
F0018 13–07 17:03
F0009 12–07 15:11
F0040 12–07 15:08
F0026 11–06 14:58
OK
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn HSP 8 LUCCA-II-RLU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn HSP 8 LUCCA-II-RLU in the language / languages: English as an attachment in your email.

The manual is 1.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn HSP 8 LUCCA-II-RLU

Haas-Sohn HSP 8 LUCCA-II-RLU User Manual - German - 32 pages

Haas-Sohn HSP 8 LUCCA-II-RLU User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info