13. Cleaning and maintenance work (see Appliance sheet 3+4.)
14. Faults, causes, correction
You can correct simple operating faults yourself with the following guide. For further information please consult
your specialist dealer.
WARNING
If a fault occurs, you will be shown this on the display.
In the event of a fault, do not pull the mains plug out straight away, so that the internal safety functions
can continue to operate fully. Only in this way can the flue gases present be extracted via the chimney
using the fan. Only pull out the mains plug before starting work on the cold appliance.
14.1. Fault error code Fxxx
Code Cause: Correction:
F0001 A. STL triggered due to overheating
B. Fuse (F1) in the central unit is defective
C. Ignition short circuit
A. If STB has triggered - contact service
department
B. Fuse F1(3.15 A) defective - contact service
department
C. Ignition defective - contact service
department
F0002 A. Burner dirty
B. Pellet tank empty
C. Ignition defective
D. Burner not lying flush
E. Flame temperature sensor defective
F. Downpipe / screw conveyor blocked
G. Screw motor defective
A. Clean burner
B. Clean burner - fill pellet tank
C. Ignition defective - contact service
department
D. Clean burner - position burner correctly
E. Flame temperature sensor defective -
contact service department
F. Clean the intake on the screw conveyor
housing with a vacuum cleaner - clean burner
G. Screw motor defective - contact service
department
F0003 A. Heat exchanger / smoke flues dirty
B. Heating curve set too low
C. Room temperature sensor is lying on the
floor or wall
A. Cleaning the smoke flues - clean burner
B. Clean burner - Adjust heating curve as
described
C. Clean burner - suspend room temperature
sensor freely
F0005 A. Burner dirty
B. Pellet tank empty
C. Downpipe / screw conveyor blocked
D. Room too airtight required combustion air
cannot flow into the room
E. Flue gas temperature sensor defective
F. Screw motor defective
G. Pellet fuel has too low a calorific value
A. Clean burner
B. Clean burner - fill pellet tank
C. Clean the intake on the screw conveyor
housing with a vacuum cleaner. Clean
burner
D. Clean burner - Ensure adequate
combustion air
E. Flue gas temperature sensor defective -
contact service department
F. Screw motor defective - contact service
department
G. Clean burner - switch to high quality pellet
type
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn HSP 6 PALLAZZA-III-RLU-PGI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn HSP 6 PALLAZZA-III-RLU-PGI in the language / languages: English as an attachment in your email.

The manual is 1.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn HSP 6 PALLAZZA-III-RLU-PGI

Haas-Sohn HSP 6 PALLAZZA-III-RLU-PGI User Manual - German - 32 pages

Haas-Sohn HSP 6 PALLAZZA-III-RLU-PGI User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info